Literature DB >> 3962874

Comparison of Doppler-determined elevated pulmonary arterial pressure with pressure measured at cardiac catheterization.

R Martin-Duran, M Larman, A Trugeda, J A Vazquez de Prada, J Ruano, A Torres, A Figueroa, A Pajaron, F Nistal.   

Abstract

This study assesses use of pulsed Doppler echocardiography to measure pulmonary artery (PA) pressure. PA flow at the right ventricular (RV) outflow tract was analyzed in 51 patients. Attention was focused on PA flow morphologic pattern, RV systolic intervals, time to peak flow and acceleration time index. Correlation was made with PA pressure and total pulmonary resistance. Three morphologic patterns of PA flow were found: type I indicates normal PA pressure (sensitivity 85%, specificity 100%) and types II and III indicate PA hypertension (sensitivity 100%, specificity 85%). The RV preejection/RV ejection ratio, time to peak flow and acceleration time index show a good correlation coefficient improved when a logarithmic function was applied. The best correlation was achieved with time to peak flow (r = -0.77 with PA pressure, r = -0.79 with total pulmonary resistance), and especially with acceleration time index (r = -0.84 with PA pressure, r = -0.87 with total pulmonary resistance). Analysis of pulmonary flow is a reliable new tool for evaluating PA pressure and is even better for evaluating total pulmonary resistance. Acceleration time index is the parameter that correlates best with these 2 variables.

Entities:  

Mesh:

Year:  1986        PMID: 3962874     DOI: 10.1016/0002-9149(86)90627-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  20 in total

1.  Echocardiography in the assessment of complications of myocardial infarction.

Authors:  S Wilansky
Journal:  Tex Heart Inst J       Date:  1991

2.  Doppler assessment of pulmonary artery pressure in neonates at risk of chronic lung disease.

Authors:  B H Su; T Watanabe; M Shimizu; M Yanagisawa
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1997-07       Impact factor: 5.747

Review 3.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

4.  Changes in pulmonary artery pressure in infants with respiratory distress syndrome following treatment with Exosurf.

Authors:  A H Hamdan; N J Shaw
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-05       Impact factor: 5.747

5.  Elevated pulmonary artery systolic pressures are associated with a lower risk of atrial fibrillation following lung transplantation.

Authors:  Anuj Malik; Jonathan C Hsu; Charles Hoopes; Gina Itinarelli; Gregory M Marcus
Journal:  J Electrocardiol       Date:  2012-09-19       Impact factor: 1.438

6.  Noninvasive methods for determining pulmonary vascular function in children with pulmonary arterial hypertension: application of a mechanical oscillator model.

Authors:  Kendall S Hunter; Justin K Gross; Craig J Lanning; K Scott Kirby; Karrie L Dyer; D Dunbar Ivy; Robin Shandas
Journal:  Congenit Heart Dis       Date:  2008 Mar-Apr       Impact factor: 2.007

7.  A comparison of echocardiography to invasive measurement in the evaluation of pulmonary arterial hypertension in a rat model.

Authors:  Juha W Koskenvuo; Rachel Mirsky; Yan Zhang; Franca S Angeli; Sarah Jahn; Tero-Pekka Alastalo; Nelson B Schiller; Andrew J Boyle; Kanu Chatterjee; Teresa De Marco; Yerem Yeghiazarians
Journal:  Int J Cardiovasc Imaging       Date:  2010-02-07       Impact factor: 2.357

8.  Pulmonary artery pressure changes in the very low birthweight infant developing chronic lung disease.

Authors:  A B Gill; A M Weindling
Journal:  Arch Dis Child       Date:  1993-03       Impact factor: 3.791

9.  Pulmonary blood flow profiles with reduced right ventricular function in lambs.

Authors:  H Katayama; G W Henry; R Krzeski; C L Lucas; B Ha; J I Ferreiro
Journal:  Heart Vessels       Date:  1996       Impact factor: 2.037

10.  Prediction of peak pulmonary artery pressure by continuous-wave Doppler echocardiography in infants and children.

Authors:  T Akiba; M Yoshikawa; S Otaki; Y Kobayashi; M Nakasato; H Suzuki; T Sato
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.