Literature DB >> 3958336

Instantaneous pressure gradient: a simultaneous Doppler and dual catheter correlative study.

P J Currie, D J Hagler, J B Seward, G S Reeder, D A Fyfe, A A Bove, A J Tajik.   

Abstract

To more precisely measure the beat to beat and instantaneous pressure gradients across outflow stenotic lesions, simultaneous Doppler and dual catheter pressure gradient measurements were performed in 95 patients (mean age 42 years, range 1.5 to 85). There were 38 right ventricular and 62 left ventricular outflow obstructive lesions. Forty-nine patients also had a nonsimultaneous Doppler study performed within 7 days before catheterization. The simultaneous pressure waveforms and Doppler spectral velocity profiles were digitized at 10 ms intervals deriving maximal, mean and instantaneous gradients (mm Hg). For simultaneous maximal Doppler and catheter gradient measurements, the correlation coefficient (r) was 0.95 (SEE = 10 mm Hg), for Doppler and catheter mean gradients it was 0.94 (SEE = 8 mm Hg) and for maximal Doppler and peak to peak catheter gradients it was 0.92 (SEE = 13 mm Hg). The correlation of maximal and mean Doppler gradients with the respective catheter gradients was similarly high when the right and left ventricular outflow lesions were analyzed separately. However, the maximal Doppler gradient was significantly higher than the peak to peak catheter gradient. This was more evident with left ventricular outflow stenotic lesions. The correlation of the outpatient maximal Doppler and catheter gradients (r = 0.80, SEE = 17 mm Hg) was significantly lower than the simultaneous correlation (r = 0.96, SEE = 10 mm Hg) in the 49 patients with two Doppler studies. Continuous wave Doppler echocardiography accurately measures the instantaneous pressure gradient across both left and right ventricular outflow obstructive lesions. The maximal Doppler gradient should not be equated with the peak to peak catheter gradient.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3958336     DOI: 10.1016/s0735-1097(86)80339-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  21 in total

1.  Continuous wave Doppler echocardiography after surgical repair of coarctation of the aorta.

Authors:  K C Chan; D F Dickinson; G A Wharton; J L Gibbs
Journal:  Br Heart J       Date:  1992-08

Review 2.  Ultrasound and coarctation of the aorta.

Authors:  J L Gibbs
Journal:  Br Heart J       Date:  1990-08

3.  Aortic stenosis: the spectrum of practice.

Authors:  O Khalid; D M Luxenberg; C Sable; O Benavidez; T Geva; B Hanna; R Abdulla
Journal:  Pediatr Cardiol       Date:  2006-11-16       Impact factor: 1.655

Review 4.  The right ventricle in congenital heart disease.

Authors:  P A Davlouros; K Niwa; G Webb; M A Gatzoulis
Journal:  Heart       Date:  2006-04       Impact factor: 5.994

Review 5.  Problems in the diagnosis and investigation of aortic stenosis.

Authors:  A Bishop; P Wilkinson
Journal:  Postgrad Med J       Date:  1991-12       Impact factor: 2.401

6.  Variability of the Doppler gradient in pulmonary valve stenosis before and after balloon dilatation.

Authors:  M K Lim; A B Houston; W B Doig; S Lilley; E P Murtagh
Journal:  Br Heart J       Date:  1989-09

7.  Natural history and surgical outcomes for isolated discrete subaortic stenosis in children.

Authors:  C V Rohlicek; S F del Pino; M Hosking; J Miro; J M Côté; J Finley
Journal:  Heart       Date:  1999-12       Impact factor: 5.994

Review 8.  Assessment of cardiac hemodynamics and valvular function by Doppler echocardiography.

Authors:  D C Wallerson; J Dubin; R B Devereux
Journal:  Bull N Y Acad Med       Date:  1987-10

Review 9.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

10.  MRI of the pulmonary artery after arterial switch operation for transposition of the great arteries.

Authors:  F J Beek; R P Beekman; E H Dillon; W P Mali; L C Meiners; P P Kramer; E J Meyboom
Journal:  Pediatr Radiol       Date:  1993
View more