Literature DB >> 3957961

Thrombin uptake and inhibition on endothelium and surfaces with a stable heparin coating: a comparative in vitro study.

C Arnander, M Dryjski, R Larsson, P Olsson, J Swedenborg.   

Abstract

The endothelial lining and two differently heparin-coated surfaces were compared in vitro regarding thrombin uptake and inhibition. One heparin surface was based on stabilized ionic binding of heparin, the other on covalent binding of partially degraded heparin. Both heparin surfaces have previously been shown to have pronounced thromboresistant properties. The two heparinized polyethylene surfaces and the endothelial surface of segments of the porcine aorta were studied. After exposure to the surfaces, thrombin disappeared from the solution and appeared bound to the surfaces. The disappearance rate of thrombin from the solution was the same on exposure to the endothelium and the covalently bonded heparin surface, but less following exposure to the ionically bonded heparin surface. The thrombin activity appearing on the endothelium was lower than on the heparin surfaces, indicating that the endothelium exerted a slow thrombin inhibiting capacity. On exposure of the thrombin-loaded endothelium to plasma, thrombin was rapidly inhibited. Thrombin bound to the covalently bonded heparin surface was inhibited at a slower rate than on the ionically bonded surface, but still faster than the rate at which free thrombin was inhibited in nonheparinized plasma. It is concluded that the endothelium and stabilized heparin coatings bind thrombin and accelerate its inhibition by plasma.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3957961     DOI: 10.1002/jbm.820200212

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

1.  Total extracorporeal lung assist--a new clinical approach.

Authors:  T Wetterberg; S Steen
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

Review 2.  Maintaining blood flow in the extracorporeal circuit: haemostasis and anticoagulation.

Authors:  A R Webb; M G Mythen; D Jacobson; I J Mackie
Journal:  Intensive Care Med       Date:  1995-01       Impact factor: 17.440

3.  Small caliber heparin loaded ultrafine microfiber woven graft achieved high patency rate in a preliminary study of canine carotid artery implantation.

Authors:  Masaki Fujita; Nobuaki Tanaka; Yuka Sakaguchi; Yosuke Takaya; Taisuke Kogawa; Hiroshi Tsuchikura; Tadahiro Sasajima; Kazuhiro Tanahashi
Journal:  JVS Vasc Sci       Date:  2020-07-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.