Literature DB >> 3957945

Dynamic performance characteristics of the liquid metal strain gage.

T D Brown, L Sigal, G O Njus, N M Njus, R J Singerman, R A Brand.   

Abstract

Performance characteristics of the liquid metal strain gage (LMSG) were evaluated by both static and dynamic bench testing. Statically, the devices were found to have outputs closely proportional to engineering strains, up to strain levels of 40%. While individual gage factors varied appreciably (up to 50%), each of the gages studied showed excellent reproducibility of behavior. Dynamically, the response to sinusoidal strain inputs was frequency-independent up to 50 Hz, and there was no detectable phase shift. Similarly, the LMSG response to constant-speed displacement inputs was velocity-independent over the range of nominal strain rates from 20 s-1 to 0.02 s-1. The devices proved capable of maintaining stable outputs when held stretched to fixed lengths, even if such tests were performed immediately following stepwise displacement inputs. Thermal artifacts were found to be modest (0.185% apparent strain per degree C), and there was no appreciable sensitivity to non-axial strains. When mounted on an in vitro ligament preparation, the LMSG measured apparent ligament strain similar to that detected by a video dimension analyzer. A protocol by which an implanted LMSG could be used to infer in vivo muscle forces was demonstrated, based on recordings of tendo-Achilles strains developed by a rabbit during slow hopping.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3957945     DOI: 10.1016/0021-9290(86)90146-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  The measurement of anterior cruciate ligament strain in vivo.

Authors:  B Beynnon; J G Howe; M H Pope; R J Johnson; B C Fleming
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  The sensitivity of joint afferents to knee translation.

Authors:  K J Cole; R A Brand; B J Daley
Journal:  Iowa Orthop J       Date:  1995

Review 3.  Review on tension in the natural and reconstructed anterior cruciate ligament.

Authors:  H N Andersen; A A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1994       Impact factor: 4.342

4.  Estimation of dynamic, in vivo soft-tissue deformation: experimental technique and application in a canine model of tendon injury and repair.

Authors:  Michael J Bey; Stephanie K Kline; Andrew R Baker; Jesse A McCarron; Joseph P Iannotti; Kathleen A Derwin
Journal:  J Orthop Res       Date:  2010-12-23       Impact factor: 3.494

Review 5.  Techniques for In Vivo Measurement of Ligament and Tendon Strain: A Review.

Authors:  Qiang Zhang; Naomi C Adam; S H Hosseini Nasab; William R Taylor; Colin R Smith
Journal:  Ann Biomed Eng       Date:  2020-10-06       Impact factor: 3.934

6.  Upconversion Spectral Rulers for Transcutaneous Displacement Measurements.

Authors:  Melissa M Suckey; Donald W Benza; John D DesJardins; Jeffrey N Anker
Journal:  Sensors (Basel)       Date:  2021-05-20       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.