Literature DB >> 3955973

Comparison of lumbosacral fixation devices.

J W Ogilvie, M Schendel.   

Abstract

Fusion of L4 and L5 to the sacrum has a high incidence of success. Using conventional methods, nonunion is common when long scoliosis fusions are extended to the sacrum. Three methods of instrumentation for fusing the lumbar spine to the sacrum were compared on a spine simulator test stand. Harrington distraction rods from the sacral ala to L1, Luque rods from L1 to the sacrum, and Harrington compression rods from L1 to the sacrum were tested. The use of a spine instrumentation test stand discounted biologic variation in spinal structure. Sequential loading of each test stand-instrumentation construct in torsion, flexion, extension, and lateral bending gave stiffness constants (Ks) for each test mode. Test values had reproducibility of greater than 94%. Ks illustrates the inability of Harrington distraction rods to the sacrum to resist flexion and torsion, but the ability to resist lateral bend and extension. Harrington compression rod and Luque rod constructs have equivalent stiffness in flexion and torsion. Harrington compression rods efficiently resist extension, and Luque rods resist lateral bending. Harrington distraction rods have limited use in lumbosacral junction fixation other than to correct and resist lateral bending.

Entities:  

Mesh:

Year:  1986        PMID: 3955973

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  Rh-BMP-2 for L5-S1 arthrodesis in long fusions to the pelvis for neuromuscular spinal deformity in the pediatric age group: analysis of 11 patients.

Authors:  Loyola V Gressot; Akash J Patel; Steven W Hwang; Daniel H Fulkerson; Andrew Jea
Journal:  Childs Nerv Syst       Date:  2013-07-12       Impact factor: 1.475

2.  Lumbosacral fusion using the Boucher technique in combination with a posterolateral bone graft.

Authors:  M A El Masry; C J McAllen; C R Weatherley
Journal:  Eur Spine J       Date:  2003-06-11       Impact factor: 3.134

3.  Free-hand placement of iliac screws for spinopelvic fixation based on anatomical landmarks: technical note.

Authors:  Jared Fridley; Daniel Fahim; Jovany Navarro; J P Wolinsky; Ibrahim Omeis
Journal:  Int J Spine Surg       Date:  2014-12-01

4.  Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study.

Authors:  Ahmet Karakasli; Nihat Acar; Bora Uzun
Journal:  J Korean Neurosurg Soc       Date:  2018-02-28

5.  Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support.

Authors:  Shih-Hao Chen; Ruey Mo Lin; Hsiang-Ho Chen; Kai-Jow Tsai
Journal:  BMC Musculoskelet Disord       Date:  2007-03-10       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.