Literature DB >> 3954663

Electrodes for electroretinography. A comparison of four different types.

M Gjötterberg.   

Abstract

Electroretinograms of 11 healthy eyes were recorded on two occasions. Four different electrodes were used, and the B-wave amplitudes were compared. The Lovac contact lens electrode produced higher amplitudes than did the ERG-Jet lens electrode or the Burian-Allen lens electrode. The gold foil electrode gave the lowest amplitudes, but was superior in comfort.

Entities:  

Mesh:

Year:  1986        PMID: 3954663     DOI: 10.1001/archopht.1986.01050160125027

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  8 in total

1.  Alteration of electroretinographic recordings when performed under sedation or halogenate anesthesia in a pediatric population.

Authors:  François Tremblay; Joan E Parkinson
Journal:  Doc Ophthalmol       Date:  2003-11       Impact factor: 2.379

2.  Recording the oscillatory potentials of the electroretinogram with the DTL electrode.

Authors:  P Lachapelle; J Benoit; J M Little; B Lachapelle
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

3.  Comparison of guinea pig electroretinograms measured with bipolar corneal and unipolar intravitreal electrodes.

Authors:  B V Bui; H S Weisinger; A J Sinclair; A J Vingrys
Journal:  Doc Ophthalmol       Date:  1998       Impact factor: 2.379

4.  Improved contact lens electrode for corneal ERG recordings in mice.

Authors:  Botir T Sagdullaev; Paul J DeMarco; Maureen A McCall
Journal:  Doc Ophthalmol       Date:  2004-05       Impact factor: 2.379

5.  The gold foil electrode in pattern electroretinography.

Authors:  T C Prager; A M Fea; W E Sponsel; F C Schweitzer; L McNulty; C A Garcia
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

6.  Comparisons of the amplitude size and the reproducibility of three different electrodes to record the corneal flash electroretinogram in rodents.

Authors:  A U Bayer; T Mittag; P Cook; S E Brodie; S M Podos; K P Maag
Journal:  Doc Ophthalmol       Date:  1999       Impact factor: 1.854

7.  Electroretinography in dogs using a fiber electrode prototype.

Authors:  A L Pereira; F Montiani-Ferreira; V R Santos; S R Salomão; C Souza; A Berezovsky
Journal:  Braz J Med Biol Res       Date:  2013-03-19       Impact factor: 2.590

8.  Soft transparent graphene contact lens electrodes for conformal full-cornea recording of electroretinogram.

Authors:  Rongkang Yin; Zheng Xu; Ming Mei; Zhaolong Chen; Kai Wang; Yanlin Liu; Tao Tang; Manish Kr Priydarshi; Xuejuan Meng; Siyuan Zhao; Bing Deng; Hailin Peng; Zhongfan Liu; Xiaojie Duan
Journal:  Nat Commun       Date:  2018-06-13       Impact factor: 14.919