Literature DB >> 3949673

Device for rapid quantification of human carotid baroreceptor-cardiac reflex responses.

J M Sprenkle, D L Eckberg, R L Goble, J J Schelhorn, H C Halliday.   

Abstract

We designed, constructed, and evaluated a new device to characterize the human carotid baroreceptor-cardiac reflex response relation rapidly. We designed this system for study of reflex responses of astronauts before, during, and after space travel. The system comprises a new tightly sealing silicone rubber neck chamber, a stepping motor-driven electro-deposited nickel bellows pressure system, capable of delivering sequential R-wave-triggered neck chamber pressure changes between +40 and -65 mmHg, and a microprocessor-based electronics system for control of pressure steps and analysis and display of responses. This new system provokes classic sigmoid baroreceptor-cardiac reflex responses with threshold, linear, and saturation ranges in most human volunteers during one held expiration.

Entities:  

Mesh:

Year:  1986        PMID: 3949673     DOI: 10.1152/jappl.1986.60.2.727

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  11 in total

Review 1.  Baroreflex dysfunction induced by microgravity: potential relevance to postflight orthostatic intolerance.

Authors:  A C Ertl; A Diedrich; I Biaggioni
Journal:  Clin Auton Res       Date:  2000-10       Impact factor: 4.435

2.  Effects of partial neuromuscular blockade on carotid baroreflex function during exercise in humans.

Authors:  K M Gallagher; P J Fadel; M Strømstad; K Ide; S A Smith; R G Querry; P B Raven; N H Secher
Journal:  J Physiol       Date:  2001-06-15       Impact factor: 5.182

3.  Effects of exercise pressor reflex activation on carotid baroreflex function during exercise in humans.

Authors:  K M Gallagher; P J Fadel; M Strømstad; K Ide; S A Smith; R G Querry; P B Raven; N H Secher
Journal:  J Physiol       Date:  2001-06-15       Impact factor: 5.182

4.  Modulation of arterial baroreflex dynamic response during muscle metaboreflex activation in humans.

Authors:  Masashi Ichinose; Mitsuru Saito; Hiroyuki Wada; Asami Kitano; Narihiko Kondo; Takeshi Nishiyasu
Journal:  J Physiol       Date:  2002-11-01       Impact factor: 5.182

5.  A wide range of baroreflex stimulation does not alter forearm blood flow.

Authors:  Reuben Howden; J Timothy Lightfoot; Michael J Turner; Stephen J Brown; Ian L Swaine
Journal:  Eur J Appl Physiol       Date:  2004-07-27       Impact factor: 3.078

6.  Modulation of arterial baroreflex dynamic response during mild orthostatic stress in humans.

Authors:  Masashi Ichinose; Mitsuru Saito; Asami Kitano; Keiji Hayashi; Narihiko Kondo; Takeshi Nishiyasu
Journal:  J Physiol       Date:  2004-03-05       Impact factor: 5.182

7.  Whole-body heating slows carotid baroreflex response in human subjects.

Authors:  Fumio Yamazaki; Ryoko Sone
Journal:  Eur J Appl Physiol       Date:  2005-05-20       Impact factor: 3.078

8.  The arterial baroreflex and inherent G tolerance.

Authors:  Patrik Sundblad; Roger Kölegård; Pierre-Francois Migeotte; Quentin Delière; Ola Eiken
Journal:  Eur J Appl Physiol       Date:  2016-04-12       Impact factor: 3.078

9.  Carotid sinus "irritability" rather than hypersensitivity: a new name for an old syndrome?

Authors:  C R Cole; J Zuckerman; B D Levine
Journal:  Clin Auton Res       Date:  2001-04       Impact factor: 4.435

10.  Cardiovagal baroreflex gain relates to sensory loss after spinal cord injury.

Authors:  Adina E Draghici; J Andrew Taylor
Journal:  Auton Neurosci       Date:  2020-03-23       Impact factor: 3.145

View more