Literature DB >> 3948364

Wall thickness, cavity dimensions, and myocardial contractility of the left ventricle in patients with simple transposition of the great arteries. A multicenter study of patients from 10 to 20 years of age.

A M Carceller, J C Fouron, J F Smallhorn, J L Cloez, N H van Doesburg, P Mauran, G Ducharme, C Pernot, A Davignon.   

Abstract

Fifty-one patients with uncomplicated transposition of the great arteries (TGA) and normal pulmonary pressure who were 10 to 20 years old and 69 normal subjects matched for age were studied by M mode echocardiography. Left ventricular internal dimensions and posterior wall thickness showed positive correlation with the body surface area in the TGA as well as in the control groups. Values for these parameters in the TGA group were generally smaller than those in the normal population. Septal thickness of patients with TGA (5.9 +/- 1 mm) was also smaller than that in the control group (6.6 +/- 1 mm) (p less than .01). Septal motion was normal in 11 patients with TGA and paradoxical in 19 patients in this group. In the other 21 patients the septum was flat. The following systolic time intervals of the left ventricle were found for patients with TGA: preejection period (PEP) 64 +/- 11 msec, ejection time (ET) 310 +/- 37 msec, and PEP/ET 0.21 +/- 0.04. These values were significantly different from those of the right ventricle for the normal population: PEP 77 +/- 12 (p less than .01), ET 327 +/- 25 (p less than .05), and PEP/ET 0.24 +/- 0.03 (p less than .01). Shortening fraction and mean velocity of circumferential fiber shortening (49 +/- 7% and 1.6 +/- 0.3 circ/sec, respectively) were also significantly higher (p less than .01) in patients with TGA than in the control group (33 +/- 4% and 1.1 +/- 0.2 circ/sec). These data should help achieve reliable quantitative and qualitative interpretations of echocardiograms of patients with TGA.

Entities:  

Mesh:

Year:  1986        PMID: 3948364     DOI: 10.1161/01.cir.73.4.622

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  3 in total

1.  Diffuse fibrosis is common in the left, but not in the right ventricle in patients with transposition of the great arteries late after atrial switch operation.

Authors:  Nerejda Shehu; Christian Meierhofer; Daniel Messroghli; Naira Mkrtchyan; Stefan Martinoff; Peter Ewert; Heiko Stern
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-29       Impact factor: 2.357

2.  Association of Sleep Quality With Greater Left Ventricular Mass in Children Aged 9 to 11 Years.

Authors:  Brooks B Gump; Kevin S Heffernan; Kestutis Bendinskas; Bryce Hruska; James A MacKenzie; Aesoon Park; Lynn S Brann; Nader H Atallah-Yunes
Journal:  Psychosom Med       Date:  2021-04-01       Impact factor: 3.864

3.  Model of the distribution of diastolic left ventricular posterior wall thickness in healthy adults and its impact on the behavior of a string of virtual cardiomyocytes.

Authors:  Kamil Fijorek; Felix C Tanner; Barbara E Stähli; Grzegorz Gielerak; Pawel Krzesinski; Beata Uzieblo-Zyczkowska; Pawel Smurzynski; Adam Stanczyk; Katarzyna Stolarz-Skrzypek; Kalina Kawecka-Jaszcz; Marek Jastrzebski; Mateusz Podolec; Grzegorz Kopec; Barbara Stanula; Maryla Kocowska; Zofia Tylutki; Sebastian Polak
Journal:  J Cardiovasc Transl Res       Date:  2014-03-28       Impact factor: 4.132

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.