Variations in intraocular pressure during closed-system surgical procedures.

L C Moorhead, C D Armeniades.   

Abstract

True intraocular pressure (IOP) during closed-chamber anterior segment surgery and vitrectomy was measured in rabbits by inserting a miniature pressure sensor directly into the anterior chamber or into the vitreous. Infusion fluid pressure was also measured simultaneously with a sensor in the infusion line. Significant and rapid changes in IOP up to 110 mm Hg were observed during routine anterior segment and vitreous procedures. None of these IOP changes affected infusion line pressure, which was governed solely by the infusion bottle height. Furthermore, raising the infusion bottle produced minimal IOP elevation whenever fluid was flowing into and out of the eye via a surgical instrument or a wound. These results show the limitations of monitoring of infusion line pressure as a means for assessing IOP and stress the need for IOP control during surgery.

Entities:  

Mesh:

Year:  1986        PMID: 3947302     DOI: 10.1001/archopht.1986.01050140127034

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  5 in total

1.  A method for real-time intraocular pressure monitoring during scleral buckling surgery.

Authors:  D A Quillen; T W Gardner; G W Blankenship; W K Marshall
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1993-11       Impact factor: 3.117

2.  Elevated intraocular pressure causes cellular and molecular retinal injuries, advocating a more moderate intraocular pressure setting during phacoemulsification surgery.

Authors:  Zhenni Zhao; Xiaowei Yu; Xue Yang; Jiamin Zhang; Dandan Zhang; Nannan Sun; Zhigang Fan
Journal:  Int Ophthalmol       Date:  2020-07-28       Impact factor: 2.031

3.  Dynamic Pressure Measurements During Vitrectomy in a Model of the Eye.

Authors:  Irene Nepita; Alessandro Stocchino; Andrea Dodero; Maila Castellano; Mariantonia Ferrara; Mario R Romano; Rodolfo Repetto
Journal:  Transl Vis Sci Technol       Date:  2022-05-02       Impact factor: 3.048

4.  Comparison of intra-ocular pressure changes with liquid or flat applanation interfaces in a femtosecond laser platform.

Authors:  G P Williams; H P Ang; B L George; Y C Liu; G Peh; L Izquierdo; D T Tan; J S Mehta
Journal:  Sci Rep       Date:  2015-10-06       Impact factor: 4.379

5.  Impact of fluidic parameters during phacoemulsification on the anterior vitreous face behavior: Experimental study.

Authors:  Vaishali Vasavada; Samaresh Srivastava; Viraj Vasavada; Shail Vasavada; Abhay R Vasavada; Aditya Sudhalkar; Alper Bilgic
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.