Literature DB >> 3942963

TRU-CUT needle biopsy of the breast. An analysis of its specificity and sensitivity.

S Minkowitz, R Moskowitz, R A Khafif, M N Alderete.   

Abstract

One hundred fifty needle core biopsies of the breast, performed with the use of the Travenol TRU-CUT disposable needle, were done from January 1980 to November 1984. There were 112 diagnoses of breast cancer and 33 diagnoses of normal breast tissue or nonneoplastic breast disease, including 2 diagnoses of marked atypia. In five biopsy specimens, no breast tissue or tumor could be identified. Fourteen cases of malignancy were not diagnosed by TRU-CUT biopsy specimens. There were no false-positive diagnoses. Sensitivity for the diagnoses of breast cancer was 89% overall and 94% for lesions greater than 2.5 cm in diameter. The histopathologic correlation between the core biopsy specimen and the excised specimen is excellent. The core biopsy specimen permits the pathologist to accurately classify the mammary carcinoma. The overall specificity for the TRU-CUT needle biopsy is 100%, and the overall predictive value of a positive needle biopsy is 100%. A factor not apparent in all reports, whether they be fine needle aspiration or core biopsy, is the ability of the individual obtaining the tissue and the cytopathologist or pathologist interpreting the material.

Entities:  

Mesh:

Year:  1986        PMID: 3942963     DOI: 10.1002/1097-0142(19860115)57:2<320::aid-cncr2820570221>3.0.co;2-c

Source DB:  PubMed          Journal:  Cancer        ISSN: 0008-543X            Impact factor:   6.860


  4 in total

Review 1.  Value of CD15 immunostaining in diagnosing Hodgkin's disease: a review of published literature.

Authors:  P A Hall; A J D'Ardenne
Journal:  J Clin Pathol       Date:  1987-11       Impact factor: 3.411

2.  The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases.

Authors:  Mary F Dillon; Arnold D K Hill; Cecily M Quinn; Ann O'Doherty; Enda W McDermott; Niall O'Higgins
Journal:  Ann Surg       Date:  2005-11       Impact factor: 12.969

3.  Utility of Tru-Cut Biopsy of Breast Lesions - An Experience in a Regional Cancer Center of a Developing Country.

Authors:  Sagarika Samantaray; Niharika Panda; Kusumabati Besra; Lucy Pattanayak; Subrat Samantara; Sashibhusan Dash
Journal:  J Clin Diagn Res       Date:  2017-03-01

4.  Reproducibility of microvessel counts in breast cancer specimens.

Authors:  L P Marson; K M Kurian; W R Miller; J M Dixon
Journal:  Br J Cancer       Date:  1999-11       Impact factor: 7.640

  4 in total