Literature DB >> 3936527

An evaluation of the accuracy of pharmacokinetic data for the computer assisted infusion of alfentanil.

M E Ausems, D R Stanski, C C Hug.   

Abstract

The accuracy of using average alfentanil pharmacokinetic data in a computer assisted infusion pump (TIAC) to predict alfentanil plasma concentrations was tested in 35 patients (divided into three groups) receiving alfentanil and nitrous oxide in oxygen anaesthesia for lower and upper abdominal surgery. By frequently measuring the arterial plasma concentration, it was possible to determine the average prediction error for individual patients and for groups of patients. For the groups, there were no significant systematic over- or underpredictions of the alfentanil plasma concentrations (bias). However, there existed a moderate degree of variability (imprecision) within the groups, caused by deviations of measured and predicted plasma concentrations in the individual patients within each group. As a result, prediction errors of 22.2-32.5% can be expected with the average pharmacokinetic data used in this study to drive TIAC. It was concluded that, as a result of the moderate degree of imprecision, it is unwise to rely totally on the absolute values of alfentanil plasma concentrations predicted by a computer-regulated infusion pump such as TIAC. However, such devices can be used to attain rapidly a relatively stable plasma concentration that can be adjusted (titrated) to the requirements of an individual patient during anaesthesia.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3936527     DOI: 10.1093/bja/57.12.1217

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  10 in total

1.  Rate of change of blood concentrations is a major determinant of the pharmacodynamics of midazolam in rats.

Authors:  A Cleton; D Mazee; R A Voskuyl; M Danhof
Journal:  Br J Pharmacol       Date:  1999-05       Impact factor: 8.739

Review 2.  [Modern concepts in pharmacokinetics of intravenous anesthetics].

Authors:  T Heidegger; C F Minto; T W Schnider
Journal:  Anaesthesist       Date:  2004-01       Impact factor: 1.041

3.  A computer-based system for controlling plasma opioid concentration according to patient need for analgesia.

Authors:  H F Hill; R C Jacobson; B A Coda; A M Mackie
Journal:  Clin Pharmacokinet       Date:  1991-04       Impact factor: 6.447

4.  Algorithms to rapidly achieve and maintain stable drug concentrations at the site of drug effect with a computer-controlled infusion pump.

Authors:  S L Shafer; K M Gregg
Journal:  J Pharmacokinet Biopharm       Date:  1992-04

5.  Measuring the predictive performance of computer-controlled infusion pumps.

Authors:  J R Varvel; D L Donoho; S L Shafer
Journal:  J Pharmacokinet Biopharm       Date:  1992-02

6.  Estimating the rate of thiopental blood-brain equilibration using pseudo steady state serum concentrations.

Authors:  P O Maitre; M Bührer; S L Shafer; D R Stanski
Journal:  J Pharmacokinet Biopharm       Date:  1990-06

7.  Total intravenous anaesthesia.

Authors:  J S Mallon; G Edelist
Journal:  Can J Anaesth       Date:  1990-04       Impact factor: 5.063

8.  Abstracts of scientific papers: Seventh Medical Monitoring Technology Conference. March 9-12, 1987, Vail, Colorado.

Authors: 
Journal:  J Clin Monit       Date:  1987-10

9.  Plasma concentration clamping in the rat using a computer-controlled infusion pump.

Authors:  L L Gustafsson; W F Ebling; E Osaki; S Harapat; D R Stanski; S L Shafer
Journal:  Pharm Res       Date:  1992-06       Impact factor: 4.200

10.  Evaluation of the accuracy of a pharmacokinetically-based patient-controlled analgesia system.

Authors:  H Hill; A Mackie; B Coda; R Schaffer; R Jacobson; C Benedetti
Journal:  Eur J Clin Pharmacol       Date:  1992       Impact factor: 2.953

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.