Literature DB >> 3934726

Ventilatory responses when altering stride frequency at a constant oxygen uptake.

R G McMurray, L G Smith.   

Abstract

Ten women completed a slow walk (SW), fast walk (FW) and a slow run (R) on a motor driven treadmill to evaluate the effect of varying stride frequency on ventilatory responses. The treadmill grade was adjusted during the walks such that the oxygen uptake was the same as during running at 0% grade. Stride frequencies averaged 59, 69 and 80 strides/min for the SW, FW and R, respectively. Oxygen uptake was similar for all three trials (1.78 L/min); as were heart frequencies (154.6 beats/min). Mean blood pressure was unaffected by changing stride frequency. Minute ventilation was similar for all three trials (ca. 47.3 L/min). Significant differences in respiratory frequency were observed (SW = 33.2, FW = 35.4, R = 37.2 breaths/min). Tidal volumes were significantly greater during the slow walk (1417 ml) than either the fast walk (1331 ml) or the run (1301 ml). CO2 output was significantly greater during the run compared to either of the walking trials. End-tidal CO2 was 38.6 mm Hg during the slow walk and was significantly reduced during the fast walk (36.3) and run (36.0). The results suggest the existence of a mild hypocapnia during the fast walk and running exercise. These results further suggest that variations in ventilatory patterns exist during walking and running that are not totally accountable by blood pressure or CO2 and may be related to extra-metabolic stimuli.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3934726     DOI: 10.1016/0034-5687(85)90055-6

Source DB:  PubMed          Journal:  Respir Physiol        ISSN: 0034-5687


  5 in total

1.  Increased ventilation in runners during running as compared to walking at similar metabolic rates.

Authors:  M J Berry; C J Dunn; C L Pittman; W C Kerr; N E Adair
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

2.  Effects of pedal rate on respiratory responses to incremental bicycle work.

Authors:  N Takano
Journal:  J Physiol       Date:  1988-02       Impact factor: 5.182

3.  Ventilatory responses during arm and leg exercise at varying speeds and forces in untrained female humans.

Authors:  N Takano
Journal:  J Physiol       Date:  1993-08       Impact factor: 5.182

4.  Alterations in the rate of limb movement using a lower body positive pressure treadmill do not influence respiratory rate or phase III ventilation.

Authors:  Michael J Buono; Marissa Burnsed-Torres; Bethany Hess; Kristine Lopez; Catherine Ortiz; Ariel Girodo; Karen Lolli; Brett Bloom; David Bailey; Fred W Kolkhorst
Journal:  Biomed Res Int       Date:  2015-01-14       Impact factor: 3.411

5.  A variant near DHCR24 associates with microstructural properties of white matter and peripheral lipid metabolism in adolescents.

Authors:  Eeva Sliz; Jean Shin; Catriona Syme; Yash Patel; Nadine Parker; Louis Richer; Daniel Gaudet; Steffany Bennett; Tomas Paus; Zdenka Pausova
Journal:  Mol Psychiatry       Date:  2020-01-03       Impact factor: 15.992

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.