Literature DB >> 3931971

Goal-directed critiquing by computer: ventilator management.

P L Miller.   

Abstract

VQ-ATTENDING is an expert system which critiques aspects of the ventilator management of a patient receiving mechanical respiratory support. To use VQ-ATTENDING, the physician first inputs medical information describing a patient, a current set of arterial blood gas results, the current ventilator settings, and a proposed set of new ventilator settings. VQ-ATTENDING then critiques the appropriateness of the proposed settings. In its current developmental implementation, VQ-ATTENDING explores a particular expert system designed feature: the ability to assess appropriate treatment goals, and to use those goals to guide the system's critiquing analysis.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3931971     DOI: 10.1016/0010-4809(85)90020-5

Source DB:  PubMed          Journal:  Comput Biomed Res        ISSN: 0010-4809


  9 in total

1.  Medical quality assessment by scoring adherence to guideline intentions.

Authors:  A Advani; Y Shahar; M A Musen
Journal:  Proc AMIA Symp       Date:  2001

2.  A framework for evidence-adaptive quality assessment that unifies guideline-based and performance-indicator approaches.

Authors:  Aneel Advani; Mary Goldstein; Mark A Musen
Journal:  Proc AMIA Symp       Date:  2002

Review 3.  Artificial intelligence research in anesthesia and intensive care.

Authors:  G D Rennels; P L Miller
Journal:  J Clin Monit       Date:  1988-10

Review 4.  The role of medical informatics in telemedicine.

Authors:  T P Clemmer
Journal:  J Med Syst       Date:  1995-02       Impact factor: 4.460

5.  Efficacy of computerized decision support for mechanical ventilation: results of a prospective multi-center randomized trial.

Authors:  T D East; L K Heermann; R L Bradshaw; A Lugo; R M Sailors; L Ershler; C J Wallace; A H Morris; B McKinley; A Marquez; A Tonnesen; L Parmley; W Shoemaker; P Meade; P Thaut; T Hill; M Young; J Baughman; M Olterman; V Gooder; B Quinn; W Summer; V Valentine; J Carlson; K Steinberg
Journal:  Proc AMIA Symp       Date:  1999

6.  The automatic selection of ventilation parameters during the initial phase of mechanical ventilation.

Authors:  T P Laubscher; A Frutiger; S Fanconi; J X Brunner
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

7.  Automated mechanical ventilation: adapting decision making to different disease states.

Authors:  S Lozano-Zahonero; D Gottlieb; C Haberthür; J Guttmann; K Möller
Journal:  Med Biol Eng Comput       Date:  2010-11-11       Impact factor: 2.602

8.  VentSim: a simulation model of cardiopulmonary physiology.

Authors:  G W Rutledge
Journal:  Proc Annu Symp Comput Appl Med Care       Date:  1994

9.  Flex: a new computerized system for mechanical ventilation.

Authors:  Fleur T Tehrani; James H Roum
Journal:  J Clin Monit Comput       Date:  2008-03-07       Impact factor: 2.502

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.