Measurement of functional residual capacity by sulfur hexafluoride washout.

C Jonmarker, L Jansson, B Jonson, A Larsson, O Werner.   

Abstract

Measurement of functional residual capacity (FRC) by the open-circuit multiple breath tracer gas washout technique is an established method. A system based upon washout of sulfur hexafluoride (SF6) during mechanical ventilation is described. The central unit in the system is a sensitive and rapid-response infrared SF6 analyzer. SF6 is washed in until the alveolar concentration of SF6 is 0.5%, a concentration so low that the supply of other gases is hardly influenced. During washout, the flow of SF6 from the lungs is calculated by a computer every 10 ms from signals representing expiratory flow and SF6 concentration. The total volume of SF6, washed out, is calculated by integration of SF6 flow. Since the alveolar concentration at the end of washin is known, the lung volume may be obtained. The measurement procedure is highly automated and the result is presented by the computer immediately after washout. Accurate and reproducible results in model lung tests were obtained during air and N2O/O2 ventilation. Comparison with body plethysmography (FRCBOX) in eight sitting healthy subjects gave the following: FRCSF6 = 7 ml + 0.98 X FRCBOX, r = 0.99. Comparison with nitrogen washout (FRCN2) in five postoperative patients gave the following: FRCSF6 = 59 ml + 0.97 X FRCN2, r = 0.97. FRCSF6 during N2O/O2 ventilation was the same as during air/O2 ventilation in a group of paralyzed patients. The measurement system has not been tested in patients with obstructive lung disease.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3925821     DOI: 10.1097/00000542-198507000-00014

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  15 in total

1.  Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.

Authors:  Lara Brewer; Joseph Orr; Earl Fulcher; Boaz Markewitz
Journal:  J Clin Monit Comput       Date:  2011-11-06       Impact factor: 2.502

2.  Device for flow-proportional admixture of tracer gas in lung-function studies.

Authors:  D Linnarsson; H Larsson; B Jonson; A Ek; A Larsson
Journal:  Med Biol Eng Comput       Date:  1987-07       Impact factor: 2.602

3.  Automated measurement of functional residual capacity by sulfur hexafluoride washout.

Authors:  T D East; K P Andriano; N L Pace
Journal:  J Clin Monit       Date:  1987-01

4.  Functional residual capacity as a noninvasive indicator of optimal positive end-expiratory pressure.

Authors:  T D East; J C in't Veen; N L Pace; S McJames
Journal:  J Clin Monit       Date:  1988-04

5.  Monitoring of functional residual capacity by an oxygen washin/washout; technical description and evaluation.

Authors:  Dieter Weismann; Hajo Reissmann; Stefan Maisch; Bernd Füllekrug; Jochen Schulte
Journal:  J Clin Monit Comput       Date:  2006-07-11       Impact factor: 2.502

6.  Slow moderate pressure recruitment maneuver minimizes negative circulatory and lung mechanic side effects: evaluation of recruitment maneuvers using electric impedance tomography.

Authors:  Helena Odenstedt; Sophie Lindgren; Cecilia Olegård; Karin Erlandsson; Sven Lethvall; Anders Aneman; Ola Stenqvist; Stefan Lundin
Journal:  Intensive Care Med       Date:  2005-09-22       Impact factor: 17.440

7.  The recording of FRC--is it of importance and can it be made simple?

Authors:  G Hedenstierna
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

8.  A simple device to inject indicator gas for wash-out tests during mechanical ventilation.

Authors:  I Gültuna; P E Huygen; C Jabaaij; W P Holland; C Ince; H A Bruining
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

9.  A simple method to estimate functional residual capacity in mechanically ventilated patients.

Authors:  R Fretschner; H Deusch; A Weitnauer; J X Brunner
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

10.  Lung volume in mechanically ventilated patients: measurement by simplified helium dilution compared to quantitative CT scan.

Authors:  Nicolò Patroniti; Giacomo Bellani; Annamaria Manfio; Elena Maggioni; Angela Giuffrida; Giuseppe Foti; Antonio Pesenti
Journal:  Intensive Care Med       Date:  2004-01-09       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.