Literature DB >> 3918967

Combination of external beam irradiation and multiple-site perineal applicator (MUPIT) for treatment of locally advanced or recurrent prostatic, anorectal, and gynecologic malignancies.

A Martinez, G K Edmundson, R S Cox, L L Gunderson, A E Howes.   

Abstract

We have devised a single after-loading applicator, the Martinez Universal Perineal Interstitial Template (MUPIT), which has been used in combination with external beam irradiation to treat 104 patients with either locally advanced or recurrent malignancies of the cervix, vagina, female urethra, prostate, or anorectal region. Twenty-six patients treated for prostate cancer are excluded because of their short follow-up. Local failure developed in 13 of the 78 remaining patients (16.6%)--major complications developed in 4 patients (5.1%). Follow-up has been 1 year to 7 1/2 years; 60/78 patients have been followed for more than 2 years. All local recurrences and complications occurred before 18 months. The device consists of two acrylic cylinders, an acrylic template with an array of holes that serve as guides for trocars, and a cover plate. In use, the cylinders are placed in the vagina and/or rectum or both and then fastened to the template so that a fixed geometric relationship among the tumor volume, normal structures, and source placement is preserved throughout the course of the implantation. Appropriate computer programs have been developed to calculate the dose from these implants. The advantages of the system are (a) greater control of the placement of sources relative to the tumor volume and critical structures, as a result of the fixed geometry provided by the template and cylinders, and (b) improved dose-rate distributions obtained by means of computerized optimization of the source placement and strength during the planning phase. We conclude that the local control rate (83.4%) with low morbidity (5.1%) achieved with the combination of external beam irradiation and MUPIT applicator in these patients with locally advanced malignancies represents an improvement over previous published results with other applicators.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3918967     DOI: 10.1016/0360-3016(85)90163-4

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  9 in total

1.  Advances in brachytherapy.

Authors:  Peter Grimm; John Sylvester
Journal:  Rev Urol       Date:  2004

2.  Intraoperative 360-deg three-dimensional transvaginal ultrasound during needle insertions for high-dose-rate transperineal interstitial gynecologic brachytherapy of vaginal tumors.

Authors:  Jessica Robin Rodgers; Jeffrey Bax; Kathleen Surry; Vikram Velker; Eric Leung; David D'Souza; Aaron Fenster
Journal:  J Med Imaging (Bellingham)       Date:  2019-04-08

3.  Recurrent squamous cell carcinoma of the anal canal. Predictors of initial treatment failure and results of salvage therapy.

Authors:  W E Longo; A M Vernava; T P Wade; M A Coplin; K S Virgo; F E Johnson
Journal:  Ann Surg       Date:  1994-07       Impact factor: 12.969

4.  High-dose-rate interstitial brachytherapy for gynecologic malignancies--dosimetric changes during treatment period.

Authors:  Tsuyoshi Onoe; Takayuki Nose; Hideomi Yamashita; Minoru Yoshioka; Takashi Toshiyasu; Takuyo Kozuka; Masahiko Oguchi; Keiichi Nakagawa
Journal:  J Radiat Res       Date:  2013-01-07       Impact factor: 2.724

5.  Vaginal tolerance of CT based image-guided high-dose rate interstitial brachytherapy for gynecological malignancies.

Authors:  Naoya Murakami; Takahiro Kasamatsu; Minako Sumi; Ryoichi Yoshimura; Ken Harada; Mayuka Kitaguchi; Shuhei Sekii; Kana Takahashi; Kotaro Yoshio; Koji Inaba; Madoka Morota; Yoshinori Ito; Jun Itami
Journal:  Radiat Oncol       Date:  2014-01-23       Impact factor: 3.481

6.  Salvage interstitial brachytherapy based on computed tomography for recurrent cervical cancer after radical hysterectomy and adjuvant radiation therapy: case presentations and introduction of the technique.

Authors:  Zhong-Shan Liu; Jie Guo; Yang-Zhi Zhao; Xia Lin; Bin Chen; Ming Zhang; Jiang-Ming Li; Xiao-Jun Ren; Bing-Ya Zhang; Tie-Jun Wang
Journal:  J Contemp Brachytherapy       Date:  2016-10-25

7.  A specially designed domed-cones template for needles (seeds) fixation and incline insertion in prostate implant brachytherapy.

Authors:  Zhao-Sheng Yin; Shi-Qiang Tang; Jun-Wen Shi; Fen Chen; Zi-Wei Li; Jia-Ming Wu; Yee-Min Jen
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

Review 8.  Evolution of Brachytherapy Applicators for the Treatment of Cervical Cancer.

Authors:  Ankur Mourya; Lalit Mohan Aggarwal; Sunil Choudhary
Journal:  J Med Phys       Date:  2021-12-31

Review 9.  MRI findings at image guided adaptive cervix cancer brachytherapy: radiation oncologist's perspective.

Authors:  Primoz Petric; Noora Mohammed-Al-Hammadi
Journal:  J Contemp Brachytherapy       Date:  2014-06-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.