Literature DB >> 3916620

Controlled study on the use of hand-held insulin dosage computers enabling conversion to and optimizing of meal-related insulin therapy regimens.

J Schrezenmeir1, H Achterberg, J Bergeler, E Küstner, W Stümer, H Hutten, J Beyer.   

Abstract

We developed a program for a pocket computer (Sharp PC-1500) enabling conversion to and optimizing of meal-related insulin injection regimens. The dosage of regular insulin injected at meal times by a penshaped device (Novo Pen) was calculated in dependence of the carbohydrate content of the ingested meal, daytime, difference of actual and target blood glucose, 4 daily glucose levels of the last 2 or 4 days and physical activity. Long-acting insulin was proposed in dependence of morning blood levels of the preceding days. The response to elevated levels was additionally determined by night values. All quantifications were based on equivalent factors reflecting relations between insulin need and blood glucose changes and carbohydrate intake, respectively. This permits a so-called "quantified adaptation", where all these factors are individually defined and steadily actualized by the computer according to the data processed during adaptation. In a controlled cross-over study 12 type 1 diabetics were treated with conventional therapy (CT = 2-3 injections daily) and computer-assisted meal-related insulin therapy (CAMIT = 3-4 injections daily), each for a 6 weeks period. Although the number of meals was reduced from 6-7 to 3-5 and carbohydrate intake was allowed to vary from day to day, parameters of metabolic control were significantly improved by CAMIT compared to CT: mean blood glucose decreased from 9.10 +/- 2.96 to 6.22 +/- 0.65 mmol/l with CAMIT and only from 8.86 +/- 1.83 to 6.91 +/- 0.90 mmol/l with CT (p less than 0.05) and HbA1 from 10.2 +/- 1.5 to 8.6 +/- 0.8% with CAMIT and only from 9.8 +/- 1.3 to 9.1 +/- 1.0% with CT.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3916620

Source DB:  PubMed          Journal:  Life Support Syst        ISSN: 0261-989X


  2 in total

1.  Comparison of glycemic response and insulin requirements after mixed meals of equal carbohydrate content in healthy, type-1, and type-2 diabetic man.

Authors:  J Schrezenmeir; F Tatò; S Tatò; E Küstner; U Krause; G Hommel; N G Asp; H Kasper; J Beyer
Journal:  Klin Wochenschr       Date:  1989-10-02

2.  Computerized management of diabetes: a synthesis of controlled trials.

Authors:  E A Balas; S A Boren; G Griffing
Journal:  Proc AMIA Symp       Date:  1998
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.