Literature DB >> 3913175

[Evaluation of myocardial perfusion based on digital subtraction angiocardiography measured contrast medium flow times].

M Haude, J Jehle, B Löss, B Pölitz, F K Schmiel, P Spiller.   

Abstract

The purpose of this study was to discover whether myocardial perfusion can be determined quantitatively by digital subtraction angiocardiography from the passage of contrast medium through the myocardium. Cineangiograms (duration 20 s) were obtained during routine coronary angiography and analyzed by means of a computerized image processing system. Regional myocardial contrast intensity was plotted versus time as a densogram for quantitative assessment. The parameter "medium rise time" showed a good reproducibility (r = 0.92). The average of medium rise time was 2.9 s in well-perfused areas, 3.7 s in less perfused areas, 5.2 s in areas with markedly reduced perfusion and 5.8 s for perfusion defects or scars using Tl-201 scintigrams as reference. The differences between the four groups were significant except between areas of markedly reduced perfusion and perfusion defects or scars (p less than 0.05). The correlation of medium rise time to the extent of the stenosis of the coronary vessel supplying the corresponding myocardial region revealed that the medium rise time on an average was 3.2 s distal to unstenosed vessels, 3.2 s distal to slightly stenosed vessels, 5.4 s distal to highly stenosed vessels and 4.7 s distal to vessel occlusion. The differences between the groups were not significant except between the groups of patients with low and high-grade coronary stenoses. These results indicate that the parameter "medium rise time" of the intensity-time curves determined by digital image processing provides a quantitative assessment of myocardial perfusion from cineangiograms.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3913175

Source DB:  PubMed          Journal:  Z Kardiol        ISSN: 0300-5860


  3 in total

1.  Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term results.

Authors:  M Haude; R Brennecke; R Erbel; M Lang; H P Deutsch; U Renneisen; J Meyer
Journal:  Int J Card Imaging       Date:  1990

Review 2.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

3.  The effect of balloon dilatation on post-stenotic myocardial perfusion before and after stimulation of coronary flow reserve: evaluation by the densitometric parameter 'mean rise time'.

Authors:  M Haude; R Brennecke; R Erbel; D Jung; E Kiefer; T Schmidt; J Meyer
Journal:  Int J Card Imaging       Date:  1988
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.