Literature DB >> 3910250

Comparison of intravenous digital subtraction angiography to conventional aortography in patients with abdominal aortic aneurysm.

L M Boxt, P D Murray, L M Perlmutt, K M Monteiro, S I Long, D P Denny, D C Levin, D P Harrington.   

Abstract

Evaluation of intravenous digital subtraction angiography (IV DSA) in patients with abdominal aortic aneurysm was performed by obtaining catheter aortograms immediately before DSA studies in ten patients. Diagnostic images were obtained in nine of ten digital subtraction examinations. Although repeat injections were necessary in six DSA and three conventional aortography cases for adequate imaging of both cephalad and caudal extension of the aneurysm, average contrast dose was 53 cc (62 cc in standard catheter studies). Renal artery stenosis was diagnosed by DSA in two of three vessels, multiple renal arteries were demonstrated by both modalities in two cases. Digital subtraction and conventional aortographic findings were proved at surgery. Intravenous DSA was shown to be useful in the preoperative evaluation of patients with abdominal aortic aneurysm.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3910250     DOI: 10.1007/bf02552864

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  12 in total

1.  Computerized fluoroscopy in real time for noninvasive visualization of the cardiovascular system. Preliminary studies.

Authors:  R A Kruger; C A Mistretta; T L Houk; S J Riederer; C G Shaw; M M Goodsitt; A B Crummy; W Zwiebel; J C Lancaster; G G Rowe; D Flemming
Journal:  Radiology       Date:  1979-01       Impact factor: 11.105

2.  Cornerstone of vascular surgery.

Authors:  J H Foster
Journal:  Arch Surg       Date:  1974-11

3.  Arteriography and abdominal aortic aneurysm.

Authors:  G K Danielson; W S Payne
Journal:  JAMA       Date:  1969-09-01       Impact factor: 56.272

4.  Intravenous angiography using digital video subtraction: x-ray imaging system.

Authors:  T W Ovitt; P C Christenson; H D Fisher; M M Frost; S Nudelman; H Roehrig; G Seeley
Journal:  AJR Am J Roentgenol       Date:  1980-12       Impact factor: 3.959

5.  Digital subtraction angiography: overview of technical principles.

Authors:  D P Harrington; L M Boxt; P D Murray
Journal:  AJR Am J Roentgenol       Date:  1982-10       Impact factor: 3.959

6.  Gastrointestinal response to minute doses of glucagon.

Authors:  R E Miller; S M Chernish; G F Greenman; D D Maglinte; B D Rosenak; R L Brunelle
Journal:  Radiology       Date:  1982-05       Impact factor: 11.105

7.  Efficacy of glucagon for abdominal digital angiography.

Authors:  F E Rabe; H Y Yune; E C Klatte; R E Miller
Journal:  AJR Am J Roentgenol       Date:  1982-09       Impact factor: 3.959

8.  Angiography in the management of aneurysms of the abdominal aorta. Its value and safety.

Authors:  D C Brewster; A Retana; A C Waltman; R C Darling
Journal:  N Engl J Med       Date:  1975-04-17       Impact factor: 91.245

9.  Digital subtraction angiography of the human cardiovascular system.

Authors:  T F Meaney; M A Weinstein; E Buonocore; W Pavlicek; G P Borkowski; J H Gallagher; B Sufka; W J MacIntyre
Journal:  AJR Am J Roentgenol       Date:  1980-12       Impact factor: 3.959

10.  Computerized fluoroscopy: digital subtraction for intravenous angiocardiography and arteriography.

Authors:  A B Crummy; C M Strother; J F Sackett; D L Ergun; C G Shaw; R A Kruger; C A Mistretta; W D Turnipseed; R P Lieberman; P D Myerowitz; F F Ruzicka
Journal:  AJR Am J Roentgenol       Date:  1980-12       Impact factor: 3.959

View more
  1 in total

1.  Digital subtraction angiography: the intravenous approach.

Authors:  D Beyer; W Gross-Fengels; K F Neufang
Journal:  Int J Card Imaging       Date:  1988
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.