Literature DB >> 3907280

Ultrasonic assessment of abdominal venous return. I. Effect of cardiac action and respiration on mean velocity pattern, cross-sectional area and flow in the inferior vena cava and portal vein.

H J Smith, P Grøttum, S Simonsen.   

Abstract

Duplex scanning, i.e. combined real time ultrasonography and pulsed Doppler velocity measurement, of the inferior vena cava and portal vein was performed in 85 patients subjected to routine left and right heart catheterization. Mean blood velocity and volume blood flow in the inferior vena cava were found to be pulsatile, reflecting both cardiac action and respiration. Different flow patterns could be related to various heart conditions. The cross-sectional area of the inferior vena cava was also pulsatile, the normal variation with respiration being partial collapse during inspiration and maximum distension at end expiration. In the majority of patients, portal vein flow showed variation with respiration only, maximum flow occurring during expiration. The flow patterns found in the two veins were well in accordance with previous invasive findings in animals. It is concluded that duplex scanning is a useful tool in the assessment of abdominal venous return.

Entities:  

Mesh:

Year:  1985        PMID: 3907280     DOI: 10.1177/028418518502600514

Source DB:  PubMed          Journal:  Acta Radiol Diagn (Stockh)        ISSN: 0567-8056


  5 in total

1.  Measurement of normal portal venous blood flow by Doppler ultrasound.

Authors:  H S Brown; M Halliwell; M Qamar; A E Read; J M Evans; P N Wells
Journal:  Gut       Date:  1989-04       Impact factor: 23.059

2.  To-and-fro waveforms in the left gastric vein in portal hypertension.

Authors:  Shoichi Matsutani; Hideaki Mizumoto
Journal:  J Med Ultrason (2001)       Date:  2011-11-29       Impact factor: 1.314

Review 3.  Comprehensive Assessment of Fluid Status by Point-of-Care Ultrasonography.

Authors:  Eduardo R Argaiz; Abhilash Koratala; Nathaniel Reisinger
Journal:  Kidney360       Date:  2021-05-27

4.  Pulsed Doppler echocardiographic assessment of portal venous flow patterns in patients after the Fontan operation.

Authors:  J Arisawa; S Morimoto; J Ikezoe; H Naitoh; H Yamagami; T Kozuka; T Sano; Y Shimazaki; H Matsuda
Journal:  Br Heart J       Date:  1993-01

5.  Arrival time parametric imaging of the hemodynamic balance changes between the hepatic artery and the portal vein during deep inspiration, using Sonazoid-enhanced ultrasonography: A case of Budd-Chiari syndrome.

Authors:  Noritaka Wakui; Ryuji Takayama; Yasushi Matsukiyo; Naohisa Kamiyama; Kojiro Kobayashi; Takanori Mukozu; Shigeru Nakano; Takashi Ikehara; Hidenari Nagai; Yoshinori Igarashi; Yasukiyo Sumino
Journal:  Exp Ther Med       Date:  2013-05-09       Impact factor: 2.447

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.