Literature DB >> 3904372

Sonographic standards for normal infant kidney length.

C E Blane, F L Bookstein, M A DiPietro, R C Kelsch.   

Abstract

Standards for kidney length in relation to size were derived from measures of 34 normal, full-term, healthy infants aged 2-56 weeks. Of six general size variables (age, weight, length, head circumference, abdominal circumference, and C7 to coccyx length), net kidney length correlated best with a combination of infant length and weight. A nomogram has been generated from these data for use by the radiologist.

Entities:  

Mesh:

Year:  1985        PMID: 3904372     DOI: 10.2214/ajr.145.6.1289

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  15 in total

1.  Sonographic renal length in Indian children.

Authors:  S Mathur; J Chandra; K P Mittal; S K Mittal; A Khurana
Journal:  Indian J Pediatr       Date:  1996 Jul-Aug       Impact factor: 1.967

Review 2.  Imaging the kidneys and urinary tract in the neonate with acute renal failure.

Authors:  I Gordon; T M Barratt
Journal:  Pediatr Nephrol       Date:  1987-07       Impact factor: 3.714

3.  Kidney dimensions in ultrasound compared to somatometric parameters in normal children.

Authors:  P A Dremsek; H Kritscher; G Böhm; O Hochberger
Journal:  Pediatr Radiol       Date:  1987

Review 4.  Sonographic assessment of renal length in children: a reappraisal.

Authors:  J M Zerin; C E Blane
Journal:  Pediatr Radiol       Date:  1994

5.  Reference ranges of kidney dimensions in term newborns: sonographic measurements.

Authors:  Aydin Erdemir; Zelal Kahramaner; Bilal Arik; Gokmen Bilgili; Mehmet Tekin; Yeliz Genc
Journal:  Pediatr Radiol       Date:  2014-06-06

6.  Sonographic assessment of renal volume in Indian children.

Authors:  J Chandra; S Mathur; S K Mittal; K P Mittal
Journal:  Indian J Pediatr       Date:  1999 Mar-Apr       Impact factor: 1.967

7.  Sonographic assessment of normal kidney dimensions in the first year of life--a study of 992 healthy infants.

Authors:  Ana Vujic; Jovan Kosutic; Radovan Bogdanovic; Sergej Prijic; Biljana Milicic; Zoran Igrutinovic
Journal:  Pediatr Nephrol       Date:  2007-03-31       Impact factor: 3.714

8.  Length and volume of morphologically normal kidneys in korean children: ultrasound measurement and estimation using body size.

Authors:  Jun-Hwee Kim; Myung-Joon Kim; Sok Hwan Lim; Jieun Kim; Mi-Jung Lee
Journal:  Korean J Radiol       Date:  2013-07-17       Impact factor: 3.500

9.  Sonographic measurement of renal length in children: does the position of the patient matter?

Authors:  C W Carrico; J M Zerin
Journal:  Pediatr Radiol       Date:  1996

10.  Renal length discrepancy by ultrasound is a reliable predictor of an abnormal DMSA scan in children.

Authors:  Mahmood R Khazaei; Fiona Mackie; Andrew R Rosenberg; Gad Kainer
Journal:  Pediatr Nephrol       Date:  2007-10-26       Impact factor: 3.714

View more