Local histogram information content of ultrasound B-mode echographic texture.

G E Mailloux, M Bertrand, R Stampfler, S Ethier.   

Abstract

In the diagnostic ultrasound community, the echographic B-scan texture is an important area of investigation since it can be analyzed to characterize the histologic state of internal tissues. In the present paper, a minicomputer based system was used to digitize B-mode images and to develop a method to measure their textural information. This method is based on the concept of local information content of spatial image proposed by Lowitz (1983, 1984). It first measures the local gray-level histogram in a small square window centered on each picture element (pixel) of a digitized B-mode image. The information derived from the local histograms is then used to characterize the tissues, to partition the B-mode image into homogeneous zones of texture, to estimate to what extent a tissue is different from another, to delimit the contours of a tissue and to measure its surface. The method is illustrated on the thyroid gland but it can be applied to the study of other organs.

Mesh:

Year:  1985        PMID: 3904115     DOI: 10.1016/0301-5629(85)90108-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  ΤND: a thyroid nodule detection system for analysis of ultrasound images and videos.

Authors:  Eystratios G Keramidas; Dimitris Maroulis; Dimitris K Iakovidis
Journal:  J Med Syst       Date:  2010-09-14       Impact factor: 4.460

2.  Transmission acoustic microscopy of tissue sections (1 GHz). Histoacoustics and acoustic staining.

Authors:  E Kolodziejczyk; J M Saurel; J Bagnol; J Attal; M R Fernandez-Graf; A Saied
Journal:  Histochemistry       Date:  1988

3.  Roles of ultrasound and power Doppler ultrasound for diagnosis of Hashimoto thyroiditis in anti-thyroid marker-positive euthyroid subjects.

Authors:  Isin Ceylan; Serkan Yener; Firat Bayraktar; Mustafa Secil
Journal:  Quant Imaging Med Surg       Date:  2014-08

4.  Assessment of significance of features acquired from thyroid ultrasonograms in Hashimoto's disease.

Authors:  Robert Koprowski; Witold Zieleźnik; Zygmunt Wróbel; Justyna Małyszek; Beata Stępień; Waldemar Wójcik
Journal:  Biomed Eng Online       Date:  2012-08-16       Impact factor: 2.819

5.  Influence of the measurement method of features in ultrasound images of the thyroid in the diagnosis of Hashimoto's disease.

Authors:  Robert Koprowski; Anna Korzyńska; Zygmunt Wróbel; Witold Zieleźnik; Agnieszka Witkowska; Justyna Małyszek; Waldemar Wójcik
Journal:  Biomed Eng Online       Date:  2012-11-28       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.