The purpose of this study was to discern the existence of structural defects in removable partial denture frameworks by means of radiographs. A simple technique was described using a dental radiograph unit and routine periapical dental films. All components of removable partial denture castings were radiographed with different angulations. The visibility of defects was clear. Structural defects were located and classified in two brands of removable partial denture base metal alloys (Ticonium and Nobilium) commonly used in fabrication of removable partial denture castings. The technique described is simple, inexpensive, not time-consuming, and can be implemented with minimum instrumentation. Future studies with this radiographic method for investigation of internal defects in fixed prostheses or dental implants are recommended.Entities: