Literature DB >> 3902768

Lung water measurements with the mean transit time approach.

R M Effros.   

Abstract

The potential usefulness and limitations of the double-indicator mean transit time approach for measuring lung water are evaluated from both theoretical and empirical points of view. It is concluded that poor tissue perfusion is the most serious factor that can compromise the reliability of this approach. Replacement of the conventional water isotopes with a thermal signal enhances indicator delivery to ischemic areas but the diffusion of heat is not sufficiently rapid to permit measurements of water in macroscopic collections of fluid which remain unperfused. The frequency of pulmonary vascular obstruction in patients with pulmonary edema related to lung injury suggests that interpretation of transit time data will be complicated by uncertainties concerning perfusion. Thermal-dye measurements of lung water may prove more helpful in situations where pulmonary blood flow remains relatively uniform.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3902768     DOI: 10.1152/jappl.1985.59.3.673

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  5 in total

1.  Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia.

Authors:  P Rossi; A Oldner; M Wanecek; L G Leksell; A Rudehill; D Konrad; E Weitzberg
Journal:  Intensive Care Med       Date:  2003-02-08       Impact factor: 17.440

Review 2.  Measurement of extravascular lung water using the single indicator method in patients: research and potential clinical value.

Authors:  Lisa M Brown; Kathleen D Liu; Michael A Matthay
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2009-07-17       Impact factor: 5.464

3.  Relationships between volume and pressure measurements and stroke volume in critically ill patients.

Authors:  A J Bindels; J G van der Hoeven; A D Graafland; J de Koning; A E Meinders
Journal:  Crit Care       Date:  2000-05-15       Impact factor: 9.097

4.  The measurement of lung water.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

5.  Validation of transpulmonary thermodilution variables in hemodynamically stable patients with heart diseases.

Authors:  Matthias Peter Hilty; Daniel Peter Franzen; Christophe Wyss; Patric Biaggi; Marco Maggiorini
Journal:  Ann Intensive Care       Date:  2017-08-22       Impact factor: 6.925

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.