Literature DB >> 3896088

The cult of the Swan-Ganz catheter. Overuse and abuse of pulmonary flow catheters.

E D Robin.   

Abstract

The use of pulmonary artery flow-directed catheters has assumed epidemic proportions without clinical trials establishing improved outcome as a result of their use. During the past 10 years, however, it has become clear that improved outcome is found only in small groups of patients and that use of these catheters is associated with considerable risks of morbidity and mortality. A clinical trial is urgently needed to assess the balance between risks and benefits. While awaiting such trials, physicians should limit catheter use to circumstances in which there is a large probability that the data will result in more effective management; the measurements should only be used to answer specific questions about patient therapy. This situation will occur in a relatively small number of patients.

Entities:  

Mesh:

Year:  1985        PMID: 3896088     DOI: 10.7326/0003-4819-103-3-445

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  22 in total

1.  Prognostic value of extravascular lung water index in critically ill children with acute respiratory failure.

Authors:  Riccardo Lubrano; Corrado Cecchetti; Marco Elli; Caterina Tomasello; Giuliana Guido; Matteo Di Nardo; Raffaele Masciangelo; Elisabetta Pasotti; Maria Antonietta Barbieri; Elena Bellelli; Nicola Pirozzi
Journal:  Intensive Care Med       Date:  2010-09-29       Impact factor: 17.440

2.  Because It's There.

Authors:  T Dixon
Journal:  Can Fam Physician       Date:  1987-11       Impact factor: 3.275

3.  The current status and future directions of impedance cardiography in ICU.

Authors:  H Fuller; G Raskob; H ter Keurs; R Hull
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

4.  Partial Volume Effect and Correction for 3-D Color Flow Acquisition of Volumetric Blood Flow.

Authors:  Oliver D Kripfgans; Jonathan M Rubin; Stephen Z Pinter; James Jago; Ron Leichner; J Brian Fowlkes
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-08-09       Impact factor: 2.725

5.  Guidelines for reading literature reviews.

Authors:  A D Oxman; G H Guyatt
Journal:  CMAJ       Date:  1988-04-15       Impact factor: 8.262

6.  Measurement of right atrial oxygen saturation by fiberoptic oximetry accurately reflects mixed venous oxygen saturation in swine.

Authors:  G G Davies; J Mendenhall; T Symreng
Journal:  J Clin Monit       Date:  1988-04

7.  Preoperative optimization of cardiovascular hemodynamics improves outcome in peripheral vascular surgery. A prospective, randomized clinical trial.

Authors:  J F Berlauk; J H Abrams; I J Gilmour; S R O'Connor; D R Knighton; F B Cerra
Journal:  Ann Surg       Date:  1991-09       Impact factor: 12.969

8.  Current practice regarding invasive monitoring in intensive care units in Finland. A nationwide study of the uses of arterial, pulmonary artery and central venous catheters and their effect on outcome. The Finnish Intensive Care Study Group.

Authors:  E Saarela; A Kari; P Nikki; V Rauhala; E Iisalo; L Kaukinen
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

9.  Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill.

Authors:  Konrad Reinhart; Hans-Jörg Kuhn; Christiane Hartog; Donald L Bredle
Journal:  Intensive Care Med       Date:  2004-06-09       Impact factor: 17.440

10.  Perforation of the right ventricle induced by pulmonary artery catheter at induction of anesthesia for the surgery for liver transplantation: a case report and reviewed of literature.

Authors:  Maria Auxiliadora-Martins; Erick Apinagés Dos Santos; Daniel Adans Wenzinger; Gil Cezar Alkmim-Teixeira; Gerardo Cristino de M Neto; Ajith Kumar Sankarankutty; Orlando de Castro E Silva; Olindo Assis Martins-Filho; Anibal Basile-Filho
Journal:  Case Rep Med       Date:  2009-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.