Literature DB >> 3893249

Interruption of the inferior vena cava for the prevention of recurrent pulmonary embolism.

M Mansour, A E Chang, W F Sindelar.   

Abstract

Pulmonary embolism in high-risk patients may be minimized by inferior vena caval interruption by ligation, plication, intraluminal filters, or intraluminal balloons. Vena caval filter implantation is the least traumatic of all surgical methods of preventing pulmonary embolism. These nonocclusive methods are preferred to minimize the possible sequelae of venous insufficiency. The prevention of septic emboli requires complete ligation of the inferior vena cava. The transvenous approach to caval interruption by intraluminal filters is particularly useful in severely ill patients. When major surgical procedures are performed for the purpose of caval interruption, the intra-abdominal approach has greater associated mortality and morbidity than does the retroperitoneal approach. The Mobin-Uddin and Kim-Ray Greenfield filters are at present the most frequently used modalities for prevention of fatal pulmonary embolism when intervention is required. In large series of patients where intraluminal caval filters have been utilized, there has been an operative mortality of under 1 per cent, with an incidence of recurrent emboli of under 2 per cent, and an incidence of venous stasis sequelae of approximately 20 per cent. Some clinicians prefer the Greenfield filter over the Mobin-Uddin umbrella because of greater ease and flexibility of placement. In general, however, both transvenous intraluminal filters have been used effectively with acceptable mortality and morbidity, and the device used might properly be determined by the experience of the surgeon.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3893249

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  5 in total

Review 1.  Surgical treatment of acute deep venous thrombosis.

Authors:  R S Lord; F C Chen; T J Devine; I V Benn
Journal:  World J Surg       Date:  1990 Sep-Oct       Impact factor: 3.352

2.  Recurrent pulmonary embolism after inferior vena caval interruption with a Greenfield filter.

Authors:  W E Richenbacher; R G Atnip; D B Campbell; J A Waldhausen
Journal:  World J Surg       Date:  1989 Sep-Oct       Impact factor: 3.352

3.  In vitro evaluation of caval filters.

Authors:  J D Robinson; M T Madison; D W Hunter; W R Castaneda-Zuniga; K Amplatz
Journal:  Cardiovasc Intervent Radiol       Date:  1988-12       Impact factor: 2.740

4.  Clinical correlates of angiographically diagnosed idiopathic pulmonary hypertension.

Authors:  H H Gray; J M Morgan; I H Kerr; G A Miller
Journal:  Thorax       Date:  1990-06       Impact factor: 9.139

5.  Effectiveness of an inferior vena caval filter as a preventive measure against pulmonary thromboembolism after abdominal surgery.

Authors:  K Yonezawa; N Yokoo; T Yamaguchi
Journal:  Surg Today       Date:  1999       Impact factor: 2.549

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.