Literature DB >> 3891135

A Doppler-two-dimensional echocardiographic method for quantitation of mitral regurgitation.

K J Ascah, W J Stewart, L Jiang, J L Guerrero, J B Newell, L D Gillam, A E Weyman.   

Abstract

A noninvasive method to accurately quantitate the severity of mitral insufficiency would be of major clinical value. In theory, in the absence of confounding variables, regurgitant mitral flow should represent the difference between forward mitral blood flow and aortic blood flow. Since Doppler-two-dimensional echocardiographic (D2DE) methods for measuring transvalvular mitral and aortic flow have been validated, it should be possible to use mitral and aortic flows derived by this method to calculate regurgitant mitral flow. To assess the validity and accuracy of this combined approach for quantitation of regurgitant flow, we developed an open-chest canine preparation in which we could simulate, vary, and accurately measure degrees of mitral regurgitation. Seven animals were anesthetized and prepared to allow controlled right heart output. Mitral regurgitation was than simulated by placing a flexible conduit incorporating a one-way valve and electromagnetic flowmeter between the left ventricular apex and left atrium. Flow through the tube (effective mitral regurgitation) was varied between 0.2 and 1.8 liters/min and forward cardiac output ranged between 0.5 and 4 liters/min. Transmitral and transaortic flows were calculated by previously reported Doppler methods. Doppler-derived estimates of forward flow through the aortic valve correlated well with the flow measured by flowmeter (r = .92), and regurgitant flow and regurgitant fraction calculated by the D2DE approach also compared well with those measured by flowmeter (r = .84 and .83, respectively). This study demonstrates that mitral regurgitant flow and regurgitant fraction calculated by the D2DE method provide an acceptable measure of both absolute regurgitant flow and the regurgitant fraction in the experimental setting.

Entities:  

Mesh:

Year:  1985        PMID: 3891135     DOI: 10.1161/01.cir.72.2.377

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  6 in total

Review 1.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

2.  Mitral valve regurgitation: accurate blood flow quantification with MRI.

Authors:  J J M Westenberg; J Doornbos; J J Bax; M G Danilouchkine; R J van der Geest; G Labadie; H J Lamb; M I M Versteegh; A de Roos; R A E Dion; J H C Reiber
Journal:  Neth Heart J       Date:  2004-09       Impact factor: 2.380

3.  Direct measurement of vena contracta area by real-time 3-dimensional echocardiography for assessing severity of mitral regurgitation.

Authors:  Chaim Yosefy; Judy Hung; Sarah Chua; Mordehay Vaturi; Thanh-Thao Ton-Nu; Mark D Handschumacher; Robert A Levine
Journal:  Am J Cardiol       Date:  2009-10-01       Impact factor: 2.778

4.  Non-invasive measurement of the regurgitant fraction by pulsed Doppler echocardiography in isolated pure mitral regurgitation.

Authors:  C Tribouilloy; W F Shen; M A Slama; H Dufossé; D Choquet; A Marek; J P Lesbre
Journal:  Br Heart J       Date:  1991-10

5.  [Doppler echocardiography quantification of the regurgitant blood volume in patients with mitral valve insufficiency].

Authors:  H Dittmann; W Voelker; K R Karsch; L Seipel
Journal:  Klin Wochenschr       Date:  1989-09-15

6.  The clinical assessment of Doppler cardiac ultrasound in valvular heart disease.

Authors:  B C Thwaites; L M Shapiro; R M Donaldson
Journal:  J R Coll Physicians Lond       Date:  1987-07