Literature DB >> 3885793

Effect of cardiac output on extravascular lung water estimates made with the Edwards lung water computer.

K D Fallon, R E Drake, G A Laine, J C Gabel.   

Abstract

The Edwards lung water computer system uses the thermal-dye indicator technique to estimate the lung extravascular fluid volume (EVLW). The authors tested the effect of changes in cardiac output (CO) on EVLW estimates made with the lung water computer in six dogs anesthetized with halothane. Baseline CO was 2.5 +/- 1.3 l/min (mean +/- SD); CO subsequently was increased either by 220% or decreased by 70% by either giving 0.5 mg/kg of isoproterenol or increasing the inspired halothane (1-4%), respectively. There was a significant correlation between the estimated EVLW and CO in each animal (P less than 0.05) such that a 50% decrease in CO from baseline caused an approximately 40% increase in estimated EVLW. Postmortem examination showed that the lungs were not edematous, even though the lung water computer data indicated that severe pulmonary edema had developed at reduced COs. At increased COs, estimated EVLW decreased. The authors conclude that the Edwards lung water computer overestimates lung water, possibly because the thermal indicator diffuses into nonpulmonary as well as pulmonary tissue. The overestimate is greatest at low cardiac outputs.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3885793     DOI: 10.1097/00000542-198504000-00022

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation.

Authors:  M Lichtwarck-Aschoff; J Zeravik; U J Pfeiffer
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

2.  Commercial double-indicator-dilution densitometer using heavy water: evaluation in oleic-acid pulmonary edema.

Authors:  L G Leksell; M S Schreiner; A Sylvestro; G R Neufeld
Journal:  J Clin Monit       Date:  1990-04

3.  Measurement of extravascular lung water by thermal-dye dilution technique: mechanisms of cardiac output dependence.

Authors:  C J Wickerts; J Jakobsson; C Frostell; G Hedenstierna
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

4.  Influence of cardiac output on thermal-dye extravascular lung water (EVLW) in cardiac patients.

Authors:  J Boldt; D Kling; B von Bormann; H H Scheld; G Hempelmann
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

5.  Measurement of extravascular lung water during abdominal aortic surgery.

Authors:  S Kowalski; A R Downs; C Lye; L Oppenheimer
Journal:  Can J Anaesth       Date:  1989-05       Impact factor: 5.063

6.  The measurement of lung water.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.