Literature DB >> 3878288

Improved quality and information in thyroid scintigraphy.

M Bähre, H Luig, D Emrich, N Neumann, P Neumann, M Rosenfeld.   

Abstract

We compared rectilinear scanning, analogous gamma-camera imaging and imaging using a gamma camera interfaced to a computer in order to determine which of these techniques is superior for thyroid scintigraphy. Forty patients with and without goitre and irregular activity distribution were imaged using each of the three techniques. The sets of three scintigrams per patient were rated by seven physicians. These ratings were statistically analysed using a new distribution-free test. Thyroid scintigraphy using a gamma camera interfaced to a computer turned out to be the best method, especially for detecting circumscribed areas of increased uptake. We conclude that this was due to a combination of the following factors: a computer matrix of 128 X 128 pixels in combination with an acquisition zoom of 1.5, the high count density of the scintigrams, computer-controlled documentation after data acquisition and the use of a continuous grey scale for documentation. The improved quality and information content of the scintigrams obtained using a gamma-camera/computer system could improve the diagnostic value of thyroid scintigraphy, especially when the scintigrams are also evaluated quantitatively.

Entities:  

Mesh:

Year:  1985        PMID: 3878288     DOI: 10.1007/bf00279067

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  15 in total

1.  THE USE OF THE GAMMA CAMERA IN THE INVESTIGATION OF THYROID DISORDERS.

Authors:  P MURRAY; J A THOMSON
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1963-08

2.  Computer-assisted thyroidal technetium uptake measurement using a short pinhole-to-surface distance.

Authors:  D I Armstrong; T G Rogers; B E Brownlie
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1975-01

Review 3.  Technical considerations in in vivo thyroid studies.

Authors:  J W Keyes; J H Thrall; J E Carey
Journal:  Semin Nucl Med       Date:  1978-01       Impact factor: 4.446

4.  20-Min 99mTc thyroid uptake: a simplified method using the gamma camera.

Authors:  H P Higgins; D Ball; S Eastham
Journal:  J Nucl Med       Date:  1973-12       Impact factor: 10.057

5.  Measurement of thyroidal technetium uptake with the gamma camera and computer system.

Authors:  H L Atkins; J F Klopper
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1973-08

6.  The scintillation camera with pinhole collimator in thyroid imaging.

Authors:  P J Hurley; H W Strauss; P Pavoni; J K Langan; H N Wagner
Journal:  Radiology       Date:  1971-10       Impact factor: 11.105

7.  Thyroid scintiphotography in 1,000 patients: rational use of 99m Tc and 131 I compounds.

Authors:  P M Weber; I A Jasko; L V Dos Remedios
Journal:  J Nucl Med       Date:  1971-10       Impact factor: 10.057

8.  Improvement of scintigrams by computer processing.

Authors:  S M Pizer; A E Todd-Pokropek
Journal:  Semin Nucl Med       Date:  1978-04       Impact factor: 4.446

9.  Thyroid scanning using the gamma camera.

Authors:  Y Wang
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1966-08

10.  Evolution of autonomy in idiopathic non-toxic goiter, evaluated by regional suppressibility of 99mTc-uptake and TSH response to TRH.

Authors:  H Dige-Petersen; O J Clemmensen; L Hummer
Journal:  Nuklearmedizin       Date:  1976-08       Impact factor: 1.379

View more
  2 in total

Review 1.  An update on diagnostic methods in the investigation of diseases of the thyroid.

Authors:  M J Reinhardt; E Moser
Journal:  Eur J Nucl Med       Date:  1996-05

2.  Iterative reconstruction of thyroidal SPECT images.

Authors:  W Eschner; M Bähre; H Luig
Journal:  Eur J Nucl Med       Date:  1987
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.