A computerised dichromatic earpiece densitometer for the measurement of cardiac output.

P S Robinson, A Crowther, B S Jenkins, M M Webb-Peploe, D J Coltart.   

Abstract

This study assesses a precalibrated dichromatic earpiece densitometer and microprocessor for the measurement of cardiac output by indocyanine green dye dilution. The measured cardiac output is compared with values of cardiac output simultaneously determined using a cuvette densitometer. The microprocessor computation of cardiac output agreed very closely with the cardiac output determined by manual calculation from the same dye dilution curves (standard deviation +/- 1.47%). The reproducibility of the earpiece densitometer (standard deviation +/- 5.2%) was virtually identical to that of the cuvette densitometer (+/- 5.3%). In a comparison of earpiece and cuvette densitometers for 60 measurements of cardiac output following pulmonary arterial injection of dye and for 50 measurements following femoral venous injection of dye, correlation coefficients were 0.83 and 0.78 and the standard deviations of the differences of simultaneous measurements were 7.2% and 8.3% respectively. The instrument offers an accurate reproducible and relatively noninvasive technique for measuring cardiac output.

Entities:  

Mesh:

Year:  1979        PMID: 385143     DOI: 10.1093/cvr/13.7.420

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  6 in total

1.  Captopril in elderly patients with heart failure.

Authors:  P J Murphy; T Van der Cammen; J Malone-Lee
Journal:  Br Med J (Clin Res Ed)       Date:  1986-07-26

Review 2.  Cardiac output measurements. A review of current techniques and research.

Authors:  K C Ehlers; K C Mylrea; C K Waterson; J M Calkins
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

3.  Dependence of the cardiovascular effects of pindolol on the individual sympathetic nervous activity.

Authors:  N Tanaka; K Kawahira; A Kudo; T Kashima; H Tanaka
Journal:  Eur J Clin Pharmacol       Date:  1982       Impact factor: 2.953

4.  Inaccuracies in using aortic valve gradients alone to grade severity of aortic stenosis.

Authors:  M J Griffith; C Carey; D J Coltart; B S Jenkins; M M Webb-Peploe
Journal:  Br Heart J       Date:  1989-11

5.  Acute haemodynamic and metabolic effects of dopexamine, a new dopaminergic receptor agonist, in patients with chronic heart failure.

Authors:  J R Dawson; D S Thompson; M Signy; S M Juul; P Turnbull; B S Jenkins; M M Webb-Peploe
Journal:  Br Heart J       Date:  1985-09

6.  Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise.

Authors:  S H Thomas
Journal:  Br J Clin Pharmacol       Date:  1992-12       Impact factor: 4.335

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.