Literature DB >> 3850859

A randomized study comparing a transparent polyurethane dressing to a dry gauze dressing for peripheral intravenous catheter sites.

D E Craven, D A Lichtenberg, L M Kunches, A T McDonough, M I Gonzalez, T C Heeren, W R McCabe.   

Abstract

We studied rates of peripheral intravenous (IV) catheter tip and insertion site colonization after randomly assigning patients to transparent polyurethane (TP) dressings (N = 316) or dry gauze (DG) dressings (N = 421). The study was conducted during both summer and fall seasons, in a facility which lacked air conditioning. All patients had a teflon plastic catheter inserted, maintained and cultured by a member of the IV therapy team; no antibiotic or antiseptic ointments were used. Colonization rates were higher in the summer than in the fall for both catheter tips (9.0% vs 3.5%, p = 0.005) and sites (21.6% vs 7.0%, p = 0.001). During the summer season, the rate of catheter tip colonization with TP dressings was nearly twice that of DG dressings (12.4% vs 6.8%, p = 0.04). Logistic regression analysis indicated that catheter tip colonization was associated with the summer season (odds ratio = 3.0, 95% CI 1.4-6.2) and TP dressings (odds ratio = 1.8, 95% CI 1.1-3.2), and that site colonization was associated with both summer (odds ratio = 4.0, 95% CI 2.2-7.1) and receipt of antibiotics (odds ratio = 1.9, 95% CI 1.1-3.2). Coagulase-negative staphylococci were isolated from 55.5% of the colonized catheter tips and insertion sites. The data suggest that bacterial colonization of peripheral IV catheters is increased in summer, and that use of TP dressings may increase both tip colonization and cost nearly twofold.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3850859     DOI: 10.1017/s0195941700063323

Source DB:  PubMed          Journal:  Infect Control        ISSN: 0195-9417


  3 in total

1.  Possible role of capillary action in pathogenesis of experimental catheter-associated dermal tunnel infections.

Authors:  G L Cooper; A L Schiller; C C Hopkins
Journal:  J Clin Microbiol       Date:  1988-01       Impact factor: 5.948

2.  Gauze vs. plastic for peripheral intravenous dressings: testing a new technology.

Authors:  B Littenberg; L Thompson
Journal:  J Gen Intern Med       Date:  1987 Nov-Dec       Impact factor: 5.128

3.  Comparative efficacy of 13 antimicrobial dressings and different securement devices in reducing catheter-related bloodstream infections: A Bayesian network meta-analysis.

Authors:  Fang-Ping Dang; Hui-Ju Li; Jin-Hui Tian
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

  3 in total