Literature DB >> 3842274

Magnetic resonance (MR) cine imaging of the human heart.

J C Waterton, J P Jenkins, X P Zhu, H G Love, I Isherwood, D J Rowlands.   

Abstract

A novel approach has been developed for MR cine imaging of the human heart by a modified ECG-gated 2DFT method. A pulse sequence has been devised to minimise the effects of saturation which can be anticipated in sequences that require rapid pulsing. Five frames are produced at the same anatomical level at predetermined intervals during the cardiac cycle. The total time taken to achieve this data is 8 minutes. Additional frames can be interleaved by repeating the sequence with an ECG-gated delay. The anatomical sections, which can be in any orthogonal plane, are then displayed as a cine loop. Cine display in the coronal plane has been used to examine 10 volunteers and 12 patients. In addition to the morphological feature displayed in single slice ECG-gated imaging, areas of dyskinesia can be detected and subjective estimates have been made of left ventricular function.

Entities:  

Mesh:

Year:  1985        PMID: 3842274     DOI: 10.1259/0007-1285-58-692-711

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Time-resolved MRI after ingestion of liquids reveals motility changes after laparoscopic sleeve gastrectomy--preliminary results.

Authors:  Tobias Baumann; Simon Kuesters; Jodok Grueneberger; Goran Marjanovic; Lisa Zimmermann; Arnd-Oliver Schaefer; Ulrich Theodor Hopt; Mathias Langer; Wojciech Konrad Karcz
Journal:  Obes Surg       Date:  2011-01       Impact factor: 4.129

Review 2.  Principles of the magnetic resonance imaging movie method for articulatory movement.

Authors:  Midori Yoshida; Eiichi Honda; Erika Ozawa; Sayuri Maristela Inoue-Arai; Hiroko Ohmori; Keiji Moriyama; Takashi Ono; Tohru Kurabayashi; Hozumi Yoshihara; Kulthida Nunthayanon Parakonthun
Journal:  Oral Radiol       Date:  2018-09-14       Impact factor: 1.852

3.  Assessment of regional left ventricular function by magnetic resonance.

Authors:  S R Underwood; R S Rees; P E Savage; R H Klipstein; D N Firmin; K M Fox; P A Poole-Wilson; D B Longmore
Journal:  Br Heart J       Date:  1986-10

4.  Crown years for non-invasive cardiovascular imaging (Part III): 30 years cardiovascular magnetic resonance.

Authors:  E E van der Wall
Journal:  Neth Heart J       Date:  2013-06       Impact factor: 2.380

5.  Influence of orthodontic appliance-derived artifacts on 3-T MRI movies.

Authors:  Erika Ozawa; Ei-Ichi Honda; Kulthida Nunthayanon Parakonthun; Hiroko Ohmori; Kazuo Shimazaki; Tohru Kurabayashi; Takashi Ono
Journal:  Prog Orthod       Date:  2018-02-19       Impact factor: 2.750

6.  Line scan-based rapid magnetic resonance imaging of repetitive motion.

Authors:  Hankyeol Lee; Jeongtaek Lee; Jang-Yeon Park; Seung-Kyun Lee
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.