An attenuated projector-backprojector for iterative SPECT reconstruction.

G T Gullberg, R H Huesman, J A Malko, N J Pelc, T F Budinger.   

Abstract

A new ray-driven projector-backprojector which can easily be adapted for hardware implementation is described and simulated in software. The projector-backprojector discretely models the attenuated Radon transform of a source distributed within an attenuating medium as line integrals of discrete pixels, obtained using the standard sampling technique of averaging the emission source or attenuation distribution over small square regions. Attenuation factors are calculated for each pixel during the projection and backprojection operations instead of using precalculated values. The calculation of the factors requires a specification of the attenuation distribution, estimated either from an assumed constant distribution and an approximate body outline or from transmission measurements. The distribution of attenuation coefficients is stored in memory for efficient access during the projection and backprojection operations. The reconstruction of the source distribution is obtained by using a conjugate gradient or SIRT type iterative algorithm which requires one projection and one backprojection operation for each iteration.

Mesh:

Year:  1985        PMID: 3840265     DOI: 10.1088/0031-9155/30/8/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Assessment of geometrical distortion and activity distribution after attenuation correction: A SPECT phantom study.

Authors:  Sara Lappi; Simonetta Lazzari; Graziella Sarti; Pierluigi Pieri
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

4.  Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-02-14       Impact factor: 9.236

Review 5.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 6.  Attenuation correction in cardiac positron emission tomography and single-photon emission computed tomography.

Authors:  S L Bacharach; I Buvat
Journal:  J Nucl Cardiol       Date:  1995 May-Jun       Impact factor: 5.952

Review 7.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

8.  Whole body distribution of 99mTc labelled autologous human granulocytes and radiation dose to cells and organs.

Authors:  A Skretting; H B Benestad; E Sundrehagen
Journal:  Eur J Nucl Med       Date:  1988

9.  A postprocessing method for compensation of scatter and collimator blurring in SPECT: a proof-of-concept study.

Authors:  Yan Yan; Gengsheng Lawrence Zeng
Journal:  J Nucl Med Technol       Date:  2009-05-15

10.  Scatter and blurring compensation in inhomogeneous media using a postprocessing method.

Authors:  Yan Yan; Gengsheng L Zeng
Journal:  Int J Biomed Imaging       Date:  2009-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.