Literature DB >> 3839011

Membrane electrical properties and prediction of motor-unit type of medial gastrocnemius motoneurons in the cat.

J E Zengel, S A Reid, G W Sypert, J B Munson.   

Abstract

Membrane electrical properties [time constant, action potential afterhyperpolarization (AHP), rheobase, input resistance, and axonal conduction velocity] were measured in motoneurons of cat medial gastrocnemius (MG) motor units. Motor units were classified on the basis of their mechanical responses as fast twitch, fast fatiguing (FF); fast twitch with intermediate fatigue resistance (FI); fast twitch, fatigue resistant (FR); or slow twitch, fatigue resistant (S; 11, 22). Motoneuron membrane time constant, estimated from the voltage response at the onset or termination of long (50-100 ms) current pulses and corrected for voltage-response nonlinearities (32), was found to differ significantly among the major motor-unit types, increasing in the order FF less than FR less than S. Afterhyperpolarization magnitude, half-decay time, and duration were all significantly greater for the fast (FF + FI + FR) versus the slow (S) motor units. The AHP half-decay time was correlated with muscle unit twitch time over the entire motoneuron population and within the type S motor-unit population. There was no significant correlation between twitch time and AHP half-decay time among the types FF and FR motor-unit populations. In agreement with previous studies, we found a significant difference in both rheobase and input resistance among the major motor-unit types, with rheobase increasing in the order S less than FR less than FF and input resistance decreasing in that order (S greater than FR greater than FF). The differences in input resistance were present both before and after correcting for voltage-response nonlinearities (32). Also in agreement with previous studies, the mean axonal conduction velocity was significantly faster among the fast (FF + FI + and FR) compared with the slow (S) motor units. These data were used to examine the properties alone to determine motor-unit type, which has traditionally been defined on the basis of the muscle unit's mechanical properties (11, 22). We used a discriminant analysis program to classify 73 mechanically typed motor units for which we had measures of rheobase, input resistance, membrane time constant, and AHP half-decay time. This model was able to properly classify 71 of the 73 motor units of this data set, indicating that the motor units of this data set could be grouped into three categories representing the three major motor-unit types (FF, FR, and S) on the basis of their rheobase, input resistance, membrane time constant, and AHP half-decay time.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1985        PMID: 3839011     DOI: 10.1152/jn.1985.53.5.1323

Source DB:  PubMed          Journal:  J Neurophysiol        ISSN: 0022-3077            Impact factor:   2.714


  93 in total

1.  Neurotrophin modulation of the monosynaptic reflex after peripheral nerve transection.

Authors:  L M Mendell; R D Johnson; J B Munson
Journal:  J Neurosci       Date:  1999-04-15       Impact factor: 6.167

2.  Motoneurons have different membrane resistance during fictive scratching and weight support.

Authors:  Marie-Claude Perreault
Journal:  J Neurosci       Date:  2002-09-15       Impact factor: 6.167

3.  Time coupling of skeletomotor discharges in response to pseudo-random transsynaptic and transmembrane stimulation.

Authors:  R Anastasijević; K Jovanović; M Ljubisavljević; J Vuco
Journal:  Biol Cybern       Date:  1991       Impact factor: 2.086

4.  Alterations in motoneuron properties induced by acute dorsal spinal hemisection in the decerebrate cat.

Authors:  J S Carp; R K Powers; W Z Rymer
Journal:  Exp Brain Res       Date:  1991       Impact factor: 1.972

5.  Asymmetric electrotonic coupling between the soma and dendrites alters the bistable firing behaviour of reduced models.

Authors:  Hojeong Kim; Kelvin E Jones
Journal:  J Comput Neurosci       Date:  2010-10-13       Impact factor: 1.621

6.  Sensorimotor function is modulated by the serotonin receptor 1d, a novel marker for gamma motor neurons.

Authors:  Anders Enjin; Katarina E Leão; Sanja Mikulovic; Pierre Le Merre; Warren G Tourtellotte; Klas Kullander
Journal:  Mol Cell Neurosci       Date:  2012-01-17       Impact factor: 4.314

7.  Frequency-dependent amplification of stretch-evoked excitatory input in spinal motoneurons.

Authors:  Randall K Powers; Paul Nardelli; T C Cope
Journal:  J Neurophysiol       Date:  2012-05-16       Impact factor: 2.714

8.  Afterhyperpolarization-firing rate relation of turtle spinal neurons.

Authors:  E K Stauffer; D G Stuart; J C McDonagh; T G Hornby; R M Reinking
Journal:  J Comp Physiol A Neuroethol Sens Neural Behav Physiol       Date:  2004-12-10       Impact factor: 1.836

9.  A simulation study to examine the effect of common motoneuron inputs on correlated patterns of motor unit discharge.

Authors:  Madeleine M Lowery; Zeynep Erim
Journal:  J Comput Neurosci       Date:  2005-10       Impact factor: 1.621

10.  Age-related change in duration of afterhyperpolarization of human motoneurones.

Authors:  M Piotrkiewicz; L Kudina; J Mierzejewska; M Jakubiec; I Hausmanowa-Petrusewicz
Journal:  J Physiol       Date:  2007-10-11       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.