Abstract

From 1978 to 1982, 102 tibial shaft fractures in 100 patients were treated with a dynamic compression plate in our trauma center. Only 61 fractures were operated upon primarily. 84 fractures were followed for an average of 19,8 months. The mean hospital stay was 21.5 days. Postoperative minor would problems were present in ten fractures. The infection rate was 1.2% and non-union developed in 1.2%. In six fractures a second stabilisation was necessary. 88.1% of the patients had a good end result. The plate osteosynthesis of closed and first degree open tibial shaft fractures proved to be a reliable treatment procedure, when it is made by expert surgeons and in accordance with the AO-principles of fracture treatment.

Entities:  

Mesh:

Year:  1986        PMID: 3824688     DOI: 10.1007/bf02585841

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  8 in total

1.  [Plate osteosynthesis of closed tibial shaft fractures].

Authors:  K P Schmit-Neuerburg
Journal:  Orthopade       Date:  1984-09       Impact factor: 1.087

2.  [A new classification of soft-tissue damage in open and closed fractures (author's transl)].

Authors:  H Tscherne; H J Oestern
Journal:  Unfallheilkunde       Date:  1982-03

3.  [Experimental and practical basis of prebending of the narrow and broad AO plate (DCP) (author's transl)].

Authors:  L Gotzen; N Haas; G Strohfeld
Journal:  Unfallheilkunde       Date:  1981-03

4.  Operating of tibia shaft fractures?

Authors:  M Allgöwer; S M Perren
Journal:  Unfallheilkunde       Date:  1980-05

5.  [The importance of the fibula for stability in plate osteosynthesis of the tibia (author's transl)].

Authors:  L Gotzen; N Haas; J Hütter; W Köller
Journal:  Unfallheilkunde       Date:  1978-05

6.  Tibial shaft fractures treated by rigid internal fixation: the early results in a 4-year series.

Authors:  J Thunold; J E Varhaug; T Bjerkest
Journal:  Injury       Date:  1975-11       Impact factor: 2.586

7.  Fractures of the shaft of the tibia treated with AO-compression osteosynthesis.

Authors:  J Christensen; J Greiff; S Rosendahl
Journal:  Injury       Date:  1982-01       Impact factor: 2.586

8.  Experience with the AO method in the treatment of 142 cases of fresh fracture of the tibial shaft treated in the UK.

Authors:  R L Batten; L J Donaldson; M J Aldridge
Journal:  Injury       Date:  1978-11       Impact factor: 2.586

  8 in total
  1 in total

1.  The difficult healing of segmental fractures of the tibial shaft.

Authors:  P M Rommens; W Coosemans; P L Broos
Journal:  Arch Orthop Trauma Surg       Date:  1989       Impact factor: 3.067

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.