Literature DB >> 3823955

High resolution computed tomography of knee menisci.

L S Steinbach, C A Helms, R E Sims, T Gillespy, H K Genant.   

Abstract

Sixty four menisci in 22 patients were examined by non-contrast high resolution computed tomography (CT). Fifty four menisci were imaged on a GE 8800 CT scanner. The other 10 were imaged on a GE 9800 CT scanner. Nineteen menisci were shown to be torn on arthrography and/or arthroscopy--12 medially and 7 laterally. The remaining menisci were normal. When the meniscal CTs were reviewed collectively by three observers without knowledge of arthrographic or arthroscopic results, sensitivity was 63%, specificity was 93%, and accuracy was 84%. Although only 10 menisci were imaged on the GE 9800 scanner, the sensitivity in this subset of scans was 83%, the specificity 100%, and the accuracy was 90%. These results suggest that noncontrast CT cannot replace arthrography or arthroscopy, but it is possible that images obtained on the GE 9800 or comparable CT scanner may be accurate enough to be used for screening of meniscal tears in selected patients.

Entities:  

Mesh:

Year:  1987        PMID: 3823955     DOI: 10.1007/bf00349921

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  10 in total

1.  Meniscus tears of the knee: prospective evaluation with CT.

Authors:  L G Manco; J H Kavanaugh; J J Fay; B S Bilfield
Journal:  Radiology       Date:  1986-04       Impact factor: 11.105

2.  CT diagnosis of torn meniscus.

Authors:  R K DeRamos
Journal:  Comput Radiol       Date:  1982 Sep-Oct

3.  Prearthrotomy diagnostic evaluation of the knee: review of 100 cases diagnosed by arthrography and arthroscopy.

Authors:  E M Levinsohn; B E Baker
Journal:  AJR Am J Roentgenol       Date:  1980-01       Impact factor: 3.959

4.  Meniscal tears of the knee: evaluation by high-resolution CT combined with arthrography.

Authors:  B Ghelman
Journal:  Radiology       Date:  1985-10       Impact factor: 11.105

5.  Meniscal lesions of the knee joint: CT diagnosis.

Authors:  R Passariello; F Trecco; F de Paulis; C Masciocchi; G Bonanni; B B Zobel
Journal:  Radiology       Date:  1985-10       Impact factor: 11.105

6.  Accuracy of double-contrast arthrography and arthroscopy of the knee joint.

Authors:  C J Thijn
Journal:  Skeletal Radiol       Date:  1982       Impact factor: 2.199

7.  Computer-assisted tomography of the knee.

Authors:  H Pavlov; R H Freiberger; M F Deck; J L Marshall; J K Morrissey
Journal:  Invest Radiol       Date:  1978 Jan-Feb       Impact factor: 6.016

8.  Meniscal tears on knee arthrography: patterns of arthrographic abnormalities.

Authors:  A A De Smet
Journal:  Skeletal Radiol       Date:  1985       Impact factor: 2.199

9.  Arthroscopy and arthrography of the knee: a critical review.

Authors:  J Ireland; E L Trickey; D J Stoker
Journal:  J Bone Joint Surg Br       Date:  1980-02

10.  Computed tomography of the knee with reference to meniscal tears. A preliminary report.

Authors:  A G Jurik; J Jørgensen; O Helmig; A de Carvalho
Journal:  Acta Radiol Diagn (Stockh)       Date:  1984
  10 in total