Literature DB >> 3820044

Variability analysis of fetal heart rate signals as obtained from abdominal electrocardiographic recordings.

S Cerutti, G Baselli, S Civardi, E Ferrazzi, A M Marconi, M Pagani, G Pardi.   

Abstract

The present paper introduces an original method of digital signal processing for an automatic analysis of non-invasive abdominal ECG recordings on pregnant women starting from the 25th week of gestation. The procedure has been implemented on a DEC-VAX 750 digital computer at the Department of Electrical Engineering, Polytechnic of Milano and the signals are recorded at the Department of Obstetrics and Gynecology "L. Mangiagalli", University of Milano, Italy. The experimental results presented in here are still preliminary as only few cases have been considered up to now (about 20) and the goal of the paper is mainly focused on the algorithmic aspects of the whole procedure implemented in the computer and on the approach of heart rate variability (HRV) signal analysis both in the mother and in the fetus. Abdominal ECG lead processing is illustrated starting from the step of maternal (M) and fetal (F) QRS recognitions through linear digital filtering (derivative and low-pass FIR filter, Weber-Cappellini window) and weighted averaging techniques synchronized with maternal QRS's. Figure 1 a shows the original abdominal lead; figure 1 b the filtered signal for MQRS recognitions; figure 2 a the template of maternal cardiac cycle as obtained after the averaging operation synchronized with the instants of MQRS occurrence. The subtraction of the template results in the abdominal lead shown in figure 1 c in which the contribution of MECG is practically entirely reduced even in the case of MQRS and FQRS overlapping.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3820044     DOI: 10.1515/jpme.1986.14.6.445

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  15 in total

1.  Detection of fetal electrocardiogram signals using matched filters with adaptive normalisation.

Authors:  N M Gibson; M S Woolfson; J A Crowe
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

2.  Effects of fetal respiratory movements on the short-term fractal properties of heart rate variability.

Authors:  M R Ortiz; J C Echeverría; J Alvarez-Ramírez; A Martínez; M A Peña; M T García; C Vargas-García; R González-Camarena
Journal:  Med Biol Eng Comput       Date:  2012-12-16       Impact factor: 2.602

3.  Mitigating the effect of non-stationarity in spectral analysis-an application to neonate heart rate analysis.

Authors:  Rathinaswamy B Govindan; An N Massaro; Nickie Niforatos; Adré du Plessis
Journal:  Comput Biol Med       Date:  2013-10-01       Impact factor: 4.589

4.  [Fetal magnetocardiography].

Authors:  P van Leeuwen
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-09

5.  Can power spectral analysis of heart rate variability identify a high risk subgroup of congestive heart failure patients with excessive sympathetic activation? A pilot study before and after heart transplantation.

Authors:  A Mortara; M T La Rovere; M G Signorini; P Pantaleo; G Pinna; L Martinelli; C Ceconi; S Cerutti; L Tavazzi
Journal:  Br Heart J       Date:  1994-05

6.  Is there evidence of fetal-maternal heart rate synchronization?

Authors:  Peter Van Leeuwen; Daniel Geue; Silke Lange; Dirk Cysarz; Henrik Bettermann; Dietrich H W Grönemeyer
Journal:  BMC Physiol       Date:  2003-04-17

7.  Monitoring fetal heart rate during pregnancy: contributions from advanced signal processing and wearable technology.

Authors:  Maria G Signorini; Andrea Fanelli; Giovanni Magenes
Journal:  Comput Math Methods Med       Date:  2014-01-30       Impact factor: 2.238

8.  A Combined Independent Source Separation and Quality Index Optimization Method for Fetal ECG Extraction from Abdominal Maternal Leads.

Authors:  Lucia Billeci; Maurizio Varanini
Journal:  Sensors (Basel)       Date:  2017-05-16       Impact factor: 3.576

9.  Investigation of Methods to Extract Fetal Electrocardiogram from the Mother's Abdominal Signal in Practical Scenarios.

Authors:  Sadaf Sarafan; Tai Le; Amir Mohammad Naderi; Quoc-Dinh Nguyen; Brandon Tiang-Yu Kuo; Tadesse Ghirmai; Huy-Dung Han; Michael P H Lau; Hung Cao
Journal:  Technologies (Basel)       Date:  2020-06-05

10.  Invariant heart beat span versus variant heart beat intervals and its application to fetal ECG extraction.

Authors:  Huawen Yan; Hongxing Liu; Xiaolin Huang; Ying Zhao; Junfeng Si; Tiebing Liu
Journal:  Biomed Eng Online       Date:  2014-12-12       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.