Literature DB >> 3820041

Spatial filtering of the fetal electrocardiogram.

A van Oosterom.   

Abstract

One of the basic problems in the analysis of the rhythm and the shape of the fetal ECG (FECG) is the interference caused by the electrical activity of the maternal heart (MECG). Methods devised for suppressing the maternal signals in the abdominally recorded leads obviously have to rely on differences in the characteristics of both kinds of signals. In the past various differences have been employed for this purpose such as differences in wave shape, frequency content and source location. The method presented here is based on the latter principle. The electrical sources of the fetal and maternal heart are clearly separated in space. By employing multiple abdominal leads, a linear combination of the recorded signals can be formed which acts effectively as a spatial filter. As such the filtering characteristics depend exclusively on the separation inside the human body (the electrical volume conductor) and, as such, can be expected to be independent of the temporal aspects of the recorded signals. In particular, the obtained filter is unaffected by the occurrence of ectopic beats in either the fetal or the maternal heart. The determination of the required filter (weighting coefficients) is carried out by using the technique of singular value decomposition (SVD) of the data matrix representing the sampled input signals. The filter effectively suppresses the maternal component in the filter output and optimizes the fetal component. The properties of this filter are demonstrated.

Entities:  

Mesh:

Year:  1986        PMID: 3820041     DOI: 10.1515/jpme.1986.14.6.411

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  5 in total

1.  Compact long-term recorder for the transabdominal foetal and maternal electrocardiogram.

Authors:  J F Piéri; J A Crowe; B R Hayes-Gill; C J Spencer; K Bhogal; D K James
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

2.  Complete foetal ECG morphology recording by synchronised adaptive filtration.

Authors:  D Adam; D Shavit
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

3.  Comparison of SVD methods to extract the foetal electrocardiogram from cutaneous electrode signals.

Authors:  D Callaerts; B De Moor; J Vandewalle; W Sansen; G Vantrappen; J Janssens
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

4.  A Review of Fetal ECG Signal Processing; Issues and Promising Directions.

Authors:  Reza Sameni; Gari D Clifford
Journal:  Open Pacing Electrophysiol Ther J       Date:  2010-01-01

Review 5.  Robustness of electrocardiogram signal quality indices.

Authors:  Saifur Rahman; Chandan Karmakar; Iynkaran Natgunanathan; John Yearwood; Marimuthu Palaniswami
Journal:  J R Soc Interface       Date:  2022-04-13       Impact factor: 4.118

  5 in total