Internal cardiac defibrillation: histopathology and temporal stability of defibrillation energy requirements.

E S Fain, M Billingham, R A Winkle.   

Abstract

The automatic implantable cardioverter/defibrillator is tested intraoperatively to ensure effectiveness by performing a number of induced fibrillation-defibrillation trials. The temporal stability of defibrillation energy requirements and the histopathologic effects of multiple defibrillating shocks were studied in 12 dogs chronically instrumented with an internal spring-patch lead system identical to that used in humans. Dogs were studied on days 1, 11, 18, 25 and 32. Data were analyzed by logistic regression and the energy required for 50% (E50) and 80% (E80) success was compared. On day 32 the dogs were killed and the heart was removed for gross and microscopic pathologic examination. There was a significant decrease in energy requirements from day 1 to day 11, as the E50 decreased from 6.9 +/- 4.5 to 4.9 +/- 2.5 J (p less than 0.02) and the E80 decreased from 8.5 +/- 5.2 to 6.1 +/- 3.4 J (p less than 0.02). The energy requirements then remained stable over the remainder of the experiment. The dogs were administered 209 +/- 18 shocks (range 1 to 24 J) for a total cumulative dose of 1,524 +/- 571 J. In all cases, both grossly and microscopically, there was no evidence of pathologic changes in the myocardium or coronary vessels. In all cases there was a fibrous plaque beneath the patch electrodes, at times containing an area of patchy hemorrhage; in a single specimen a mixed inflammatory infiltrate accompanied the hemorrhage. Endothelialization of the spring electrode with mild right atrial endocardial fibrosis was also observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 3819207     DOI: 10.1016/s0735-1097(87)80058-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

1.  Submuscular versus subcutaneous pectoral implantation of cardioverter-defibrillators: effect on high voltage pathway impedance and defibrillation efficacy.

Authors:  D Iskos; K Lock; K G Lurie; G J Fahy; S Petersen-Stejskal; D G Benditt
Journal:  J Interv Card Electrophysiol       Date:  1998-03       Impact factor: 1.900

2.  Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter defibrillator in Swine.

Authors:  Cheryl R Killingsworth; Sharon B Melnick; Silvio H Litovsky; Raymond E Ideker; Gregory P Walcott
Journal:  Pacing Clin Electrophysiol       Date:  2013-05-28       Impact factor: 1.976

Review 3.  The Defibrillation Conundrum: New Insights into the Mechanisms of Shock-Related Myocardial Injury Sustained from a Life-Saving Therapy.

Authors:  Nicolas Clementy; Alexandre Bodin; Arnaud Bisson; Ana-Paula Teixeira-Gomes; Sebastien Roger; Denis Angoulvant; Valérie Labas; Dominique Babuty
Journal:  Int J Mol Sci       Date:  2021-05-08       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.