Literature DB >> 3813954

Graphic presentation of computer-analyzed keratoscope photographs.

L J Maguire, D E Singer, S D Klyce.   

Abstract

We describe a corneal topography analysis system that creates accurate high-resolution graphics of corneal surface power from computer analysis of keratoscope photographs, and we present several examples of corneal shape analyses. The major improvement in the updated version presented here is the development of a contour map of corneal surface power. Improvements in computer algorithms used to analyze the raw data obtained from the keratoscope photographs have also been made, resulting in increased accuracy. This system allows the ophthalmologist to see the patterns of power distribution on the corneal surface more easily than is possible by visual inspection of keratoscope photographs. Improved corneal topography analysis should find wide clinical application in the study of refractive corneal surgery techniques and in the study of corneal disorders that cause irregular astigmatism.

Entities:  

Mesh:

Year:  1987        PMID: 3813954     DOI: 10.1001/archopht.1987.01060020077033

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  7 in total

1.  Influence of some operational variables on the radial keratotomy operation.

Authors:  J Q Wang; Y J Zeng; X Y Li
Journal:  Br J Ophthalmol       Date:  2000-06       Impact factor: 4.638

2.  One-year follow-up of epikeratophakia for keratoconus.

Authors:  R J Uusitalo; J Lehtosalo; S D Klyce
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

3.  Automated corneal topography: computerized analysis of photokeratoscope images.

Authors:  M Busin; I Wilmanns; M Spitznas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

4.  Proposed classification for topographic patterns seen after penetrating keratoplasty.

Authors:  C H Karabatsas; S D Cook; J M Sparrow
Journal:  Br J Ophthalmol       Date:  1999-04       Impact factor: 4.638

5.  Corneal topographic changes in premenopausal and postmenopausal women.

Authors:  Erdinc Aydin; Helin Deniz Demir; Fazli Demirturk; Ahmet Cantug Caliskan; Hakan Aytan; Unal Erkorkmaz
Journal:  BMC Ophthalmol       Date:  2007-05-14       Impact factor: 2.209

6.  Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Cornea       Date:  2015-08       Impact factor: 2.651

7.  Interocular Symmetry Analysis of Corneal Elevation Using the Fellow Eye as the Reference Surface and Machine Learning.

Authors:  Shiva Mehravaran; Iman Dehzangi; Md Mahmudur Rahman
Journal:  Healthcare (Basel)       Date:  2021-12-16
  7 in total