In vitro analysis of mechanisms of balloon valvuloplasty of stenotic mitral valves.

J D Kaplan, J M Isner, R H Karas, K R Halaburka, M A Konstam, T J Hougen, R J Cleveland, D N Salem.   

Abstract

Preliminary reports indicate that percutaneous balloon valvuloplasty is efficacious for treatment of mitral stenosis. The present study was designed to evaluate whether anatomic features of stenotic mitral valves in older adults affect the efficacy of balloon valvuloplasty and to determine the mechanism by which increased orifice area is accomplished. Fifteen mitral valves excised intact at the time of mitral valve replacement from patients with no more than 2+/4+ mitral a regurgitation were selected for study. Balloon valvuloplasty was performed using a sequence of dilation catheters with balloons 18 to 25 mm in inflated diameter. Mitral valve area, measured with a conical valve sizer, increased from 0.71 +/- 0.06 cm2 (mean +/- standard error of the mean) to 1.77 +/- 0.19 cm2 (p less than 0.0001) after valvuloplasty, resulting in an increase in calculated orifice area of 185 +/- 27% (range 34 to 407%). The increase in calculated orifice area correlated inversely with orifice area before valvuloplasty (r = -0.57; p = 0.026), but was unrelated to extent of calcific deposits on the prevalvuloplasty x-ray of the excised mitral valve. Gross examination together with x-ray analysis after valvuloplasty revealed that the mechanism of balloon valvuloplasty in each case involved commissural splitting, including splits through heavily calcified commissures, without grossly apparent detachment of tissue fragments. These findings suggest that balloon valvuloplasty augments the functional mitral valve orifice area in a manner analogous to standard surgical commissurotomy, and balloon valvuloplasty is likely to be efficacious for a wide spectrum of adult mitral valvular stenosis, including severe stenosis with extensive calcific deposits.

Entities:  

Mesh:

Year:  1987        PMID: 3812282     DOI: 10.1016/0002-9149(87)90806-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

1.  Balloon dilatation of heart valves.

Authors:  R Hall; R Kirk
Journal:  BMJ       Date:  1992-08-29

2.  In vitro balloon dilatation of mitral valve stenosis: the importance of subvalvar involvement as a cause of mitral valve insufficiency.

Authors:  A S Sadee; A E Becker
Journal:  Br Heart J       Date:  1991-05

3.  Transoesophageal echocardiographic assessment of mitral valve commissural morphology predicts outcome after balloon mitral valvotomy.

Authors:  N Sutaria; T R D Shaw; B Prendergast; D Northridge
Journal:  Heart       Date:  2006-01       Impact factor: 5.994

4.  Balloon dilatation of the aortic valve in a pulsatile flow model: assessment of the mechanisms and the magnitude and duration of changes in valve area and gradient.

Authors:  E Rosenthal; J K Montarello; A C Perakis; E G Boyd; M Rosin; A K Yates; P B Deverall; E Sowton; P V Curry
Journal:  Br Heart J       Date:  1990-04

5.  Assessment of mitral valve commissural morphology by transoesophageal echocardiography predicts outcome after balloon mitral valvotomy.

Authors:  D Sarath Babu; K P Ranganayakulu; D Rajasekhar; V Vanajakshamma; T Pramod Kumar
Journal:  Indian Heart J       Date:  2013-04-09

6.  Mechanics of percutaneous balloon valvotomy for mitral valvular stenosis.

Authors:  Y Matsuura; S Fukunaga; H Ishihara; Y Hamanaka; T Sueda; G Kajiyama; H Matsuura; M Okamoto; K Inoue
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

7.  Subvalvular apparatus and adverse outcome of balloon valvotomy in rheumatic mitral stenosis.

Authors:  Parag Bhalgat; Shrivallabh Karlekar; Santosh Modani; Ashish Agrawal; Charan Lanjewar; Ashish Nabar; Prafulla Kerkar; Nandu Agrawal; Pradeep Vaideeswar
Journal:  Indian Heart J       Date:  2015-08-08

8.  Long term outcome of percutaneous mitral balloon valvotomy in patients aged 70 and over.

Authors:  N Sutaria; A T Elder; T R Shaw
Journal:  Heart       Date:  2000-04       Impact factor: 5.994

9.  The predictive value of mitral leaflet motion and thickness index scores on early restenosis after mitral balloon valvuloplasty.

Authors:  Mustafa Akin; Abdi Sagcan; Sanem Nalbantgil; Filiz Ozerkan; Azem Akilli; Yavuzgil Oguz; Mehdi Zoghi
Journal:  Tex Heart Inst J       Date:  2004

10.  Balloon mitral valvuloplasty: clinical experience at the Texas Heart Institute.

Authors:  P A Tucker; J J Ferguson; M Harlan; C M Gaos; A Massumi
Journal:  Tex Heart Inst J       Date:  1992
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.