Literature DB >> 3804478

Determination of time constants in kinetic studies involving radiolabeled tracer molecules.

M E Jones, T E Nicholas, J H Power, H A Barr.   

Abstract

In tracer kinetic studies, two homogeneous well-mixed compartments may be related as precursor and product. The time constant for the product compartment can then be estimated from the two specific activity vs. time curves. We examine ten methods of estimating this time constant for data with several different error patterns, and conclude that the present practice of transforming the data to a straight line yields an inefficient but unbiased estimate of the time constant. A least squares estimate, appropriately weighted and taking into account that both precursor and product specific activities are subject to error is expected theoretically and found in practice, to be most efficient. It is however, mathematically complicated. A modified approach using a minimum chi 2 estimate in which precursor specific activities are treated as error-free, is almost as efficient. It is mathematically simple, and outperforms the currently used estimators.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3804478     DOI: 10.1016/0020-7101(86)90067-x

Source DB:  PubMed          Journal:  Int J Biomed Comput        ISSN: 0020-7101


  1 in total

1.  Turnover of cholesterol and dipalmitoyl phosphatidylcholine in surfactant of adult rat lung.

Authors:  M E Jones; H A Barr; T E Nicholas
Journal:  Lipids       Date:  1993-03       Impact factor: 1.880