Literature DB >> 3797669

Partial flip angle MR imaging.

T C Mills, D A Ortendahl, N M Hylton, L E Crooks, J W Carlson, L Kaufman.   

Abstract

Theoretical analysis predicts that performing magnetic resonance (MR) imaging with partial (less than 90 degrees) flip angles can reduce imaging times two- to fourfold when lesions with elevated T1 values are being examined. This time savings occurs because repetition time (TR) is reduced when imaging is performed with partial flips. Partial flip MR imaging can also improve signal-to-noise ratio (S/N) in fast body imaging. For this study, analytical tools were used to predict image contrast and S/N for short TR, partial flip sequences. Experimental implementation of the short TR, partial flip sequences that analytical work had predicted would be optimal supported the analytical predictions and demonstrated their validity. Partial flip MR imaging is applicable to reducing imaging time only when the ratio of signal differences to noise exceeds threshold values in conventional MR images. Partial flip sequences can be used to advantage in MR imaging of both the head and the body, and the observed effects are predictable through theoretical analysis.

Mesh:

Year:  1987        PMID: 3797669     DOI: 10.1148/radiology.162.2.3797669

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  3-D imaging of the CNS.

Authors:  V M Runge; D Y Gelblum; M L Wood
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

2.  Advantages and pitfalls in 3T MR brain imaging: a pictorial review.

Authors:  Bernd L Schmitz; Andrik J Aschoff; Martin H K Hoffmann; Georg Grön
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

3.  Enhancing gray-to-white matter contrast in 3T T1 spin-echo brain scans by optimizing flip angle.

Authors:  Bernd L Schmitz; Georg Grön; Florian Brausewetter; Martin H K Hoffmann; Andrik J Aschoff
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

4.  Multiple slice FLASH imaging: an improved pulse sequence for contrast enhanced MR brain studies.

Authors:  W Schörner; B Sander; H Henkes; T Heim; W Lanksch; R Felix
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

5.  Age-related MRI changes at 0.1 T in cervical discs in asymptomatic subjects.

Authors:  I J Lehto; M O Tertti; M E Komu; H E Paajanen; J Tuominen; M J Kormano
Journal:  Neuroradiology       Date:  1994       Impact factor: 2.804

6.  MRI assessment of experimental gliomas using 17.6 T.

Authors:  Marc A Schwarz; Mirko Pham; Xavier Helluy; Arnd Doerfler; Tobias Engelhorn
Journal:  Neuroradiology       Date:  2013-03-10       Impact factor: 2.804

  6 in total