Literature DB >> 3796308

Estimation of red cell flow microvessels: consequences of the Baker-Wayland spatial averaging model.

R N Pittman, M L Ellsworth.   

Abstract

The dual sensor cross-correlation method of H. Wayland and P.C. Johnson [1967), J. Appl. Physiol. 22, 333-337) has become a standard technique for determining the velocity of red blood cells (RBCs) in glass tubes and blood vessels. M. Baker and H. Wayland [1974), Microvasc. Res. 7, 131-143) found that under a variety of conditions the ratio of dual sensor velocity at the centerline of a glass tube to the blood velocity averaged over the lumen was close to 1.6. They provided an explanation of this factor based on spatial averaging of RBC velocity vertically through the tube as well as laterally across the face of the sensor. Their spatial averaging model could also account for the apparent blunting of RBC velocity profiles determined with the dual sensor technique. We used Baker and Wayland's spatial averaging model to calculate how the above velocity ratio depends on sensor size. A nonlinear relation between the velocity ratio and sensor size was found such that the velocity ratio varied from 1.6 to 1.33 as the ratio of sensor width to vessel or tube diameter was varied from 0 to 1. These results also hold for vessels or tubes of elliptic cross section. Some investigators have found that the velocity of red cells near the walls of blood vessels can be a substantial fraction of centerline velocity which suggests that RBC velocity distributions can be blunter than a Poiseuille distribution. We repeated the above calculation for blunted parabolic profiles and we found that the velocity ratio ranged from 1 for plug flow to 1.6 for Poiseuille flow. These calculations show that reliable estimates of RBC flow from dual sensor centerline velocity measurements require one to take into account the relative size of the sensor and blood vessel diameter as well as the bluntness of the RBC velocity distribution.

Entities:  

Mesh:

Year:  1986        PMID: 3796308     DOI: 10.1016/0026-2862(86)90072-5

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  9 in total

1.  Effect of erythrocyte aggregation and flow rate on cell-free layer formation in arterioles.

Authors:  Peng Kai Ong; Bumseok Namgung; Paul C Johnson; Sangho Kim
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-03-26       Impact factor: 4.733

Review 2.  Simulation of intraluminal gas transport processes in the microcirculation.

Authors:  J D Hellums; P K Nair; N S Huang; N Ohshima
Journal:  Ann Biomed Eng       Date:  1996 Jan-Feb       Impact factor: 3.934

3.  Changes in vasomotion pattern and local arteriolar resistance during stepwise pressure reduction.

Authors:  H H Oude Vrielink; D W Slaaf; G J Tangelder; R S Reneman
Journal:  Pflugers Arch       Date:  1989-09       Impact factor: 3.657

4.  Going beyond 20 μm-sized channels for studying red blood cell phase separation in microfluidic bifurcations.

Authors:  Sophie Roman; Adlan Merlo; Paul Duru; Frédéric Risso; Sylvie Lorthois
Journal:  Biomicrofluidics       Date:  2016-05-12       Impact factor: 2.800

Review 5.  Oxygen transport in the microcirculation and its regulation.

Authors:  Roland N Pittman
Journal:  Microcirculation       Date:  2013-02       Impact factor: 2.628

6.  Influence of tissue metabolism and capillary oxygen supply on arteriolar oxygen transport: a computational model.

Authors:  T E Moschandreou; C G Ellis; D Goldman
Journal:  Math Biosci       Date:  2011-04-01       Impact factor: 2.144

7.  The development of peripheral microvasculopathy with chronic metabolic disease in obese Zucker rats: a retrograde emergence?

Authors:  Brayden D Halvorson; Nithin J Menon; Daniel Goldman; Stephanie J Frisbee; Adam G Goodwill; Joshua T Butcher; Phoebe A Stapleton; Steven D Brooks; Alexandre C d'Audiffret; Robert W Wiseman; Julian H Lombard; Robert W Brock; I Mark Olfert; Paul D Chantler; Jefferson C Frisbee
Journal:  Am J Physiol Heart Circ Physiol       Date:  2022-07-29       Impact factor: 5.125

8.  Microvascular and tissue oxygen gradients in the rat mesentery.

Authors:  A G Tsai; B Friesenecker; M C Mazzoni; H Kerger; D G Buerk; P C Johnson; M Intaglietta
Journal:  Proc Natl Acad Sci U S A       Date:  1998-06-09       Impact factor: 11.205

9.  Accurate blood flow measurements: are artificial tracers necessary?

Authors:  Christian Poelma; Astrid Kloosterman; Beerend P Hierck; Jerry Westerweel
Journal:  PLoS One       Date:  2012-09-20       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.