Literature DB >> 3795453

Beneficial effects of atrioventricular sequential pacing on cardiac output and left ventricular filling assessed with pulsed Doppler echocardiography.

T Masuyama, K Kodama, M Uematsu, S Nanto, K Taniura, A Kitabatake, M Inoue.   

Abstract

There has been increased interest in the beneficial effects of atrio-ventricular (AV) pacing over ventricular (V) pacing. This study attempted to evaluate the changes in cardiac output and left ventricular filling dynamics when the pacing mode was switched from V pacing to AV pacing. Study population consisted of 26 patients with multiprogrammable AV pacemakers. Cardiac output was determined as a product of echocardiographically determined cross sectional area of the aortic annulus and Doppler-determined velocity integral of left ventricular outflow over systole. Left ventricular peak rapid filling rate (PFR) and peak atrial filling velocity to peak rapid filling velocity ratio (A/R) were determined from measurements at the mitral annulus. Cardiac output showed a significant improvement when the pacing mode was switched from V to AV pacing, and the percent change ranged from 3 to 73% (average 26%). The improvement in cardiac output brought about by AV synchrony was greater in patients with smaller PFR (r = -0.71, p less than 0.01) and larger A/R ratio (r = 0.77, p less than 0.01). On the other hand, PFR was greater with V pacing than with AV pacing. Greater increment of the PFR was produced by the loss of atrial contraction in patients with smaller PFR (r = -0.82, p less than 0.01) and larger A/R ratio (r = 0.76, p less than 0.01). Thus, AV pacing provides a great improvement in left ventricular filling, i.e., cardiac output, which cannot be obtained with V pacing even with the compensatory enhancement of left ventricular rapid filling. These beneficial effects of AV pacing seemed to be greater in patients with impaired left ventricular rapid filling.

Entities:  

Mesh:

Year:  1986        PMID: 3795453     DOI: 10.1253/jcj.50.799

Source DB:  PubMed          Journal:  Jpn Circ J        ISSN: 0047-1828


  4 in total

1.  A new leadless pacemaker with atrioventricular synchronous pacing replacing a still working VVI leadless pacemaker: a case report.

Authors:  Massimo Moltrasio; Rita Sicuso; Fabrizio Tundo; Claudio Tondo
Journal:  Eur Heart J Case Rep       Date:  2021-08-15

2.  Role of atrial contraction and synchrony of ventricular contraction in the optimisation of ventriculoarterial coupling in humans.

Authors:  K Yamamoto; K Kodama; T Masuyama; A Hirayama; S Nanto; M Mishima; A Kitabatake; T Kamada
Journal:  Br Heart J       Date:  1992-05

3.  Complete congenital heart block: A case of multilevel block.

Authors:  Ian W Hovis; David N Schidlow; Jeffrey P Moak
Journal:  HeartRhythm Case Rep       Date:  2017-04-29

Review 4.  Indications for permanent pacing in dogs and cats.

Authors:  R A Santilli; F Giacomazzi; D M Porteiro Vázquez; M Perego
Journal:  J Vet Cardiol       Date:  2019-01-29       Impact factor: 1.701

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.