The quantitative aspect of photoplethysmography revised.

L T Jespersen, O L Pedersen.   

Abstract

The overall transfer function of a photoplethysmograph (PPG) converting changes in intravascular volume to changes in recorder pen deflection was investigated. The specifications of the apparatus working as a red cell densitometer were assessed in vitro, and it was found that PPG output is a logarithmic function of red cell density roughly in accordance with the Lambert-Beer theorem. In an in vivo experiment it was found that PPG output is also a logarithmic function of digital intravascular volume as assessed by means of air plethysmography. It is suggested that the equation for this in vivo function is different because of a dual action of stasis, producing increases in both intravascular volume and haematocrit. Although the relative contributions of the two disparate phenomena are not assessed further, it is concluded that their joint action on PPG output can be described by a monologarithmic function. In the Appendix, sources of non-linearity in the electronics of PPG are pointed out and instructions for the use of an exponential amplifier which will linearize the overall transfer function are given.

Entities:  

Mesh:

Year:  1986        PMID: 3793670     DOI: 10.1007/bf02128146

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  9 in total

Review 1.  Noninvasive diagnostic techniques in peripheral vascular disease.

Authors:  R W Barnes
Journal:  Am Heart J       Date:  1979-02       Impact factor: 4.749

2.  Relations between cutaneous blood flow and blood content in the finger pad, forearm, and forehead.

Authors:  A B HERTZMAN; W C RANDALL; K E JOCHIM
Journal:  Am J Physiol       Date:  1947-07-01

3.  The estimation of the cutaneous blood flow with the photoelectric plethysmograph.

Authors:  A B HERTZMAN; W C RANDALL; K E JOCHIM
Journal:  Am J Physiol       Date:  1946-03

4.  Comparison of changes in blood volume and opacity in dog digital pad and tongue.

Authors:  D L Davis; C H Baker
Journal:  J Appl Physiol       Date:  1969-11       Impact factor: 3.531

5.  A method for comparing transmitted and reflected light photoelectric plethysmography.

Authors:  G Uretzky; Y Palti
Journal:  J Appl Physiol       Date:  1971-07       Impact factor: 3.531

6.  Quantitative photoplethysmography in chronic venous insufficiency: a new method of noninvasive estimation of ambulatory venous pressure.

Authors:  C S Norris; A Beyrau; R W Barnes
Journal:  Surgery       Date:  1983-11       Impact factor: 3.982

7.  Correlation between blood volume and opacity changes in the finger.

Authors:  S Hocherman; Y Palti
Journal:  J Appl Physiol       Date:  1967-08       Impact factor: 3.531

8.  Opacity pulse of individual minute arteries.

Authors:  L S D'Agrosa; A B Hertzman
Journal:  J Appl Physiol       Date:  1967-11       Impact factor: 3.531

9.  A novel principle for detection of systolic and diastolic blood pressure tested in man and rat with special reference to its applicability in rat studies.

Authors:  L T Jespersen; E O Mikkelsen; O Lederballe; N C Nyborg
Journal:  J Hypertens       Date:  1984-08       Impact factor: 4.844

  9 in total
  1 in total

1.  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method.

Authors:  E A López-Beltrán; P L Blackshear; S M Finkelstein; J N Cohn
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.