Literature DB >> 3793411

Comparative aqueous outflow facility measurements by pneumatonography and Schiotz tonography.

J G Feghali, D T Azar, P L Kaufman.   

Abstract

Tonography was performed on 36 eyes of 15 normal and 3 primary open angle glaucoma patients using pneumatonography and classical Schiotz tonography. The average values of the coefficient of outflow facility (C) for the whole sample were virtually identical with both methods. However, both intersubject and interobserver variability were significantly higher with penumatonography. Although both methods provide comparable aggregate estimates of aqueous outflow facility, we think that Schiotz tonography is more reliable than pneumatonography because of the greater mechanical stability of the Schiotz instrument on the eye. On the other hand, pneumatonography offers the advantage of a shorter test period (2 min instead of 4).

Entities:  

Mesh:

Year:  1986        PMID: 3793411

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  8 in total

1.  Circadian variation of aqueous humor dynamics in older healthy adults.

Authors:  Cherie B Nau; Mehrdad Malihi; Jay W McLaren; David O Hodge; Arthur J Sit
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-15       Impact factor: 4.799

2.  Circadian variation of aqueous dynamics in young healthy adults.

Authors:  Arthur J Sit; Cherie B Nau; Jay W McLaren; Douglas H Johnson; David Hodge
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-04       Impact factor: 4.799

3.  Aqueous Humor Dynamics of the Brown-Norway Rat.

Authors:  Kayla R Ficarrotta; Simon A Bello; Youssef H Mohamed; Christopher L Passaglia
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-05-01       Impact factor: 4.799

4.  Mechanism of action of bimatoprost, latanoprost, and travoprost in healthy subjects. A crossover study.

Authors:  K Sheng Lim; Cherie B Nau; Megan M O'Byrne; David O Hodge; Carol B Toris; Jay W McLaren; Douglas H Johnson
Journal:  Ophthalmology       Date:  2008-05       Impact factor: 12.079

5.  The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility.

Authors:  Vassilios P Kozobolis; Eleftherios I Paschalis; Nikitas C Foudoulakis; Stavrenia C Koukoula; Georgios Labiris
Journal:  Clin Ophthalmol       Date:  2010-09-07

6.  Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography.

Authors:  Arash Kazemi; Jay W McLaren; Shuai-Chun Lin; Carol B Toris; Vikas Gulati; Sayoko E Moroi; Arthur J Sit
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-01-01       Impact factor: 4.799

7.  Effect of phacoemulsification on facility of outflow.

Authors:  Pouya Alaghband; Laura Beltran-Agulló; Elizabeth Angela Galvis; Darryl R Overby; Kin Sheng Lim
Journal:  Br J Ophthalmol       Date:  2018-04-13       Impact factor: 4.638

8.  Regionally Discrete Aqueous Humor Outflow Quantification Using Fluorescein Canalograms.

Authors:  Ralitsa T Loewen; Eric N Brown; Pritha Roy; Joel S Schuman; Ian A Sigal; Nils A Loewen
Journal:  PLoS One       Date:  2016-03-21       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.