Literature DB >> 3791731

Unstable fracture dislocations of the proximal interphalangeal joint. Treatment with the force couple splint.

J M Agee.   

Abstract

The force couple splint maintains concentric joint reduction while allowing early active range of motion exercises. Sixteen cases were treated with a force couple created across the proximal interphalangeal (PIP) joint, levering the dislocated base of the middle phalanx palmarly, while simultaneously lifting the distal end of the proximal phalanx dorsally to restore joint reduction. The splint is constructed from three Kirschner wires and is activated by a single rubber band. The effect of this force couple is present through a complete range of joint motion, thereby allowing active flexion and extension of the joint during bone and soft tissue healing. The force couple splint is capable of producing good to excellent results in patients with unstable acute fracture dislocations of the PIP joint.

Entities:  

Mesh:

Year:  1987        PMID: 3791731

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  It's Not "Just A Finger".

Authors:  J A Combs
Journal:  J Athl Train       Date:  2000-04       Impact factor: 2.860

Review 2.  Complications of Proximal Interphalangeal Joint Injuries: Prevention and Treatment.

Authors:  Sirichai Kamnerdnakta; Helen E Huetteman; Kevin C Chung
Journal:  Hand Clin       Date:  2018-05       Impact factor: 1.907

Review 3.  Fracture-dislocations of the proximal interphalangeal joint.

Authors:  John Elfar; Tobias Mann
Journal:  J Am Acad Orthop Surg       Date:  2013-02       Impact factor: 3.020

4.  Early results of a simple distraction dynamic external fixator in management of comminuted intra-articular fractures of base of middle phalanx.

Authors:  Muhammad Mansha; Sanjay Miranda
Journal:  J Hand Microsurg       Date:  2013-06-19

Review 5.  [Intraarticular fractures of the proximal interphalangeal joint: dynamic early functional therapy with an external fixation system].

Authors:  E Goldberg; F Unglaub; U Kneser; R E Horch
Journal:  Unfallchirurg       Date:  2009-03       Impact factor: 1.000

6.  Treatment of Fracture-Dislocations of Proximal Interphalangeal Joint by Applying of Dynamic Mini External Fixator: Clinical and Radiographic Results.

Authors:  Parviz Ahangar; Alireza Rahimnia; Masoud Mokhtari; Amirhossein Rahimnia
Journal:  Arch Bone Jt Surg       Date:  2021-11

7.  The use of the s-quattro dynamic external fixator for the treatment of intra-articular phalangeal fractures: a review of the literature.

Authors:  J S Bhamra; W S Khan; P Pastides
Journal:  Open Orthop J       Date:  2012-02-23

8.  Modified Transosseous Wiring Technique for Neglected Fracture-Dislocation of the Proximal Interphalangeal Joint.

Authors:  Hee-June Kim; Hyun-Joo Lee; Poong-Taek Kim; Hee-Soo Kyung; Ji Won Oh; Suk-Joong Lee
Journal:  Clin Orthop Surg       Date:  2019-05-09

9.  Clinical and radiological midterm outcome after treatment of pilonoidal fracture dislocations of the proximal interphalangeal joint with a parabolic dynamic external fixator.

Authors:  T Kastenberger; P Kaiser; M Keller; G Schmidle; M Gabl; Rohit Arora
Journal:  Arch Orthop Trauma Surg       Date:  2019-09-05       Impact factor: 3.067

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.