Literature DB >> 3791604

Single-chamber cardiac pacing with activity-initiated chronotropic response: evaluation by cardiopulmonary exercise testing.

D G Benditt, M Mianulli, J Fetter, D W Benson, A Dunnigan, E Molina, C C Gornick, A Almquist.   

Abstract

In this study, sequential cardiopulmonary exercise testing was used to assess the physiologic benefits of a single-chamber ventricular pacing system that utilizes a piezoceramic sensor to adjust heart rate by detecting "physical activity." An initial exercise test was conducted with the pacemaker programmed (based on a randomization table) to either the fixed rate (VVI, 70 beats/min) or rate-variable (VVI-Act) mode, and the results were compared with those obtained during a second exercise test in which the pacemaker was programmed to the alternate pacing mode. A 1.5 to 2 hr rest period was permitted between exercise tests, each of which consisted of a symptom-limited constant speed (3.0 mph) Balke protocol with 2 min stages commencing at 0.0% grade with increments of 2.5% at end of each stage. Compared with findings during fixed-rate VVI pacing, VVI-Act pacing was associated with greater exercise-induced positive chronotropic response (mean maximum heart rate VVI-Act 128 +/- 15.3 beats/min vs VVI 90 +/- 28.4 beats/min; p less than .01), prolongation of exercise duration (VVI-Act 10.2 +/- 3.8 min vs VVI 7.7 +/- 2.5 min; p less than .01), increased peak oxygen consumption (VVI-Act 1617 +/- 656 ml O2/min vs VVI 1325 +/- 451 ml O2/min; p less than .01), and onset of anaerobic threshold at a higher oxygen consumption (VVI-Act 1208 +/- 343 ml O2/min vs VVI 1064 +/- 377 ml O2/min: p less than .01). Additionally, of 44 comparable exercise stages tested in the two pacing modes, perceived exertion (assessed by a numerical grading system) was lower in 38 of 44 instances during VVI-Act compared with VVI pacing.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 3791604     DOI: 10.1161/01.cir.75.1.184

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  9 in total

1.  Validating optimal function of the closed loop stimulation sensor with high right septal ventricular electrode placement in 'ablate and pace' patients.

Authors:  John Silberbauer; Paul S G Hong; Rick A Veasey; Nadeem A Maddekar; Wasing Taggu; Nikhil R Patel; Guy W Lloyd; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2009-07-23       Impact factor: 1.900

2.  The United Kingdom pacing and cardiovascular events (UKPACE) trial. United Kingdom Pacing and Cardiovascular Events.

Authors:  W D Toff; J D Skehan; D P De Bono; A J Camm
Journal:  Heart       Date:  1997-09       Impact factor: 5.994

3.  Physiological importance of different atrioventricular intervals to improved exercise performance in patients with dual chamber pacemakers.

Authors:  R J Haskell; W J French
Journal:  Br Heart J       Date:  1989-01

Review 4.  Pacemakers and exercise. Current status, future developments and practical implications of physiological pacemakers.

Authors:  N A Estes; G Brockington; A S Manolis; D Salem
Journal:  Sports Med       Date:  1989-07       Impact factor: 11.136

5.  Randomised crossover trial of rate responsive Activitrax and conventional fixed rate ventricular pacing.

Authors:  D P Lipkin; N Buller; M Frenneaux; L Ludgate; T Lowe; S C Webb; D M Krikler
Journal:  Br Heart J       Date:  1987-12

6.  Cardiac pacing for bradyarrhythmias in the elderly.

Authors:  R Sutton
Journal:  J R Soc Med       Date:  1994-04       Impact factor: 5.344

7.  "Value" of improved treadmill exercise capacity: lessons from a study of rate responsive pacing.

Authors:  A D Staniforth; R Andrews; M Harrison; A Perry; A J Cowley
Journal:  Heart       Date:  1998-10       Impact factor: 5.994

8.  Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block.

Authors:  M R Hargreaves; K M Channon; T R Cripps; M Gardner; O J Ormerod
Journal:  Br Heart J       Date:  1995-10

9.  Sensors for rate responsive pacing.

Authors:  Simonetta Dell'Orto; Paolo Valli; Enrico Maria Greco
Journal:  Indian Pacing Electrophysiol J       Date:  2004-07-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.