Literature DB >> 3790380

Comparability of M mode echocardiographic long axis and short axis left ventricular function derivatives.

P G D'Arbela, Z M Silayan, J M Bland.   

Abstract

M mode echocardiographic anteroposterior indexes of left ventricular function derived from long and short axis parasternal planes were compared in one hundred cases. In all the disease groups studied the paired values were within acceptable statistical limits of comparability and interchangeability; that is they were within two standard deviations of the mean difference in both directions. Values from either plane can usually be considered as being representative of the expected values for the individual.

Entities:  

Mesh:

Year:  1986        PMID: 3790380      PMCID: PMC1236891          DOI: 10.1136/hrt.56.5.445

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  6 in total

1.  Left ventricular performance assessed by radionuclide angiocardiography and echocardiography in patients with previous myocardial infarction.

Authors:  H Henning; H Schelbert; M H Crawford; J S Karliner; W Ashburn; R A O'Rourke
Journal:  Circulation       Date:  1975-12       Impact factor: 29.690

2.  Assessment of left ventricular dimensions and function by echocardiography.

Authors:  I Belenkie; D O Nutter; D W Clark; D B McCraw; A E Raizner
Journal:  Am J Cardiol       Date:  1973-06       Impact factor: 2.778

3.  Left ventricular volumes and ejection fraction by echocardiography.

Authors:  J F Pombo; B L Troy; R O Russell
Journal:  Circulation       Date:  1971-04       Impact factor: 29.690

4.  Echocardiographic evaluation of cardiac performance.

Authors:  T G DiSessa; W F Friedman
Journal:  Cardiol Clin       Date:  1983-08       Impact factor: 2.213

5.  M mode echocardiographic assessment of left ventricular function.

Authors:  R L Popp
Journal:  Am J Cardiol       Date:  1982-04-01       Impact factor: 2.778

6.  Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.

Authors:  D J Sahn; A DeMaria; J Kisslo; A Weyman
Journal:  Circulation       Date:  1978-12       Impact factor: 29.690

  6 in total
  1 in total

1.  Gene electro transfer of plasmid encoding vascular endothelial growth factor for enhanced expression and perfusion in the ischemic swine heart.

Authors:  Barbara Hargrave; Robert Strange; Sagar Navare; Michael Stratton; Nina Burcus; Len Murray; Cathryn Lundberg; Anna Bulysheva; Fanying Li; Richard Heller
Journal:  PLoS One       Date:  2014-12-29       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.