Literature DB >> 3784285

Permeability and secondary membrane formation of a high flux polysulfone hemofilter.

A Röckel, J Hertel, P Fiegel, S Abdelhamid, N Panitz, D Walb.   

Abstract

It has been assumed that the molecular weight (MW) cut-off of a newly fabricated polysulfone capillary dialyzer (F60, Fresenius, FRG) is similar to that of the human glomerulus. We recently tested the device in vivo and found this not to be so, based on the device's ability to eliminate substances of a MW of 10,000 to 60,000 daltons. One of the reasons for this discrepancy was found to be the influence of secondary membrane formation on solute permeability. Endogenous marker substances of a defined MW (beta 2-microglobulin, myoglobin, RBP, alpha 1-microglobulin, acid alpha 1-glycoprotein, alpha 1-antitrypsin, prealbumin, and albumin were measured by laser nephelometry or radioimmune assay; sieving coefficients (SC) and protein eliminations were calculated for each low MW protein.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3784285     DOI: 10.1038/ki.1986.202

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  7 in total

1.  Effect of blood flow rate on internal filtration in a high-flux dialyzer with polysulfone membrane.

Authors:  Ryoichi Sakiyama; Isamu Ishimori; Takashi Akiba; Michio Mineshima
Journal:  J Artif Organs       Date:  2012-04-26       Impact factor: 1.731

2.  Membrane fouling and dialysate flow pattern in an internal filtration-enhancing dialyzer.

Authors:  Ken-ichiro Yamamoto; Michihito Hiwatari; Fukashi Kohori; Kiyotaka Sakai; Makoto Fukuda; Tatsuo Hiyoshi
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

Review 3.  Dialysis arthropathy, amyloidosis and beta-2 microglobulin.

Authors:  J S Cameron
Journal:  Pediatr Nephrol       Date:  1987-04       Impact factor: 3.714

4.  Performance evaluation of developed polysulfone membrane hemodiafilters, ABH-F and ABH-P, in post- and pre-dilution hemodiafiltration.

Authors:  Ryoichi Sakiyama; Kenichiro Yamamoto; Isamu Ishimori; Satoshi Yoshida; Takashi Akiba; Michio Mineshima
Journal:  J Artif Organs       Date:  2015-06-10       Impact factor: 1.731

5.  Etanercept clearance during an in vitro model of continuous venovenous hemofiltration.

Authors:  Geoffrey M Fleming; Noha N Salama; Saada K Eid; Kenneth R Cooke; Bruce A Mueller
Journal:  Blood Purif       Date:  2009-09-01       Impact factor: 2.614

6.  Assessment of removal and adsorption enhancement of high-flux hemodialyzers in convective therapies by a novel in vitro uremic matrix.

Authors:  Miquel Gomez; Elisenda Bañon-Maneus; Marta Arias-Guillén; Francisco Maduell
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.379

7.  A randomized cross-over study with objective quantification of the performance of an asymmetric triacetate and a polysulfone dialysis membrane using different anticoagulation strategies.

Authors:  Floris Vanommeslaeghe; Iván Josipovic; Matthieu Boone; Annemie Dhondt; Wim Van Biesen; Sunny Eloot
Journal:  Clin Kidney J       Date:  2019-12-22
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.